In this research, a coated graphite electrode was constructed for determination of Mg2+ in pharmaceutical supplements. The designed sensor demonstrates an ideal Nernstian slope (30.1 mV. Decade-1) over a wide concentration range (1×10-6- 1×10-1 Mol L-1). The selectivity of the sensor was evaluated over 16 different cations by matched potential method and no serious interference was observed fro...
Abstract Production of piezo‐resistive auxetic sensors is usually carried out through mixing and coating methods. Although these methods are beneficial, Young's modulus mixed becomes high because using a percentage sensing elements while the durability coated gets low due to separation from sensor surface. This article presents new core–shell metamaterial model address mentioned problems. The s...
A highly selective copper (II) coated graphite sensor was prepared by 1,13-bis(8-quinolyl)- 1,4,7,10,13-pentaoxatridecane (kryptofix 5) as a supramolecule ionophore into plasticized polyvinyl chloride (PVC) membrane. The best response characteristic was observed using the membrane composition of PVC = 30.0 mg, dioctyl sebacate (DOS) = 63.5 mg, palmitic acid (PA) = 3.0 mg and kryptofix 5 = 3.5 m...
A new pyrilamine coated graphite electrode (CGE) based on pyrilamine-tetraphenylborate ion-pair (Pyra-TPB) as electroactive material has been described. The sensor exhibited a linear response with a good Nernstian slope over a relatively wide range of concentration. The membrane film of the electrode made of 3% (w/w) ion-pair, 48.5% DBP (w/w) and 48.5% PVC (w/w). The sensor displays Nernstian r...
0
in this work, all-solid-state potentiometric pvc membrane sensor was introduced for fast andsimple monitoring of mercury ions in waste water samples. the all solid sate electrode is made based on aconductive composite of graphite, reduced graphene oxide, epoxy resin on a copper wire. a thin layer pvcmembrane is then coated on the surface of the new conducting transducer. pvc membrane is compose...
Methods routinely utilized for detection of phenylalanine in new-born blood consist of enzymatic assays, lacking sensitivity and HPLC assays which are expensive and time-consuming to conduct. We, here, report for the first time, the construction of a phenylalanine sensitive electrode, on the basis of a selective molecularly imprinted polymer, offering sensitivity, economy and ease of use for th...
This study aimed to develop a contamination-free porous titanium scaffold by a plasma-activated sintering within an originally developed TiN-coated graphite mold. The surface of porous titanium sheet with or without a coated graphite mold was characterized. The cell adhesion property of porous titanium sheet was also evaluated in this study. The peak of TiC was detected on the titanium sheet pr...
Methods routinely utilized for detection of phenylalanine in new-born blood consist of enzymatic assays, lacking sensitivity and HPLC assays which are expensive and time-consuming to conduct. We, here, report for the first time, the construction of a phenylalanine sensitive electrode, on the basis of a selective molecularly imprinted polymer, offering sensitivity, economy and ease of use for th...
In order to compare and evaluate the atomization process occurring in several types of graphite furnaces for atomic absorption spectrometry, the authors estimated temporal variations in the gas temperature by using a two-line method under the assumption of a Bolzmann distribution. The atomization furnaces employed were a graphite tube, a graphite tube coated with pyrolitic carbon, a graphite tu...