نتایج جستجو برای: electric impedance imaging

تعداد نتایج: 626232  

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه رازی - دانشکده فنی و مهندسی 1388

چکیده ندارد.

2012
Thomas Widlak Otmar Scherzer

Hybrid imaging techniques utilize couplings of physical modalities – they are called hybrid, because, typically, the excitation and measurement quantities belong to different modalities. Recently there has been an enormous research interest in this area because these methods promise very high resolution. In this paper we give a review on hybrid tomography methods for electrical conductivity ima...

Journal: :anesthesiology and pain medicine 0
mehran rezvani department of anesthesiology, isfahan university of medical sciences, iran mahmoud-reza alebouyeh department of anesthesiology and pain medicine,rasoul akram medical center, iran university of medical sciences (iums), iran +98-2164352325, [email protected]; department of anesthesiology and pain medicine,rasoul akram medical center, iran university of medical sciences (iums), iran +98-2164352325, [email protected] farnad imani department of anesthesiology and pain medicine,rasoul akram medical center, iran university of medical sciences (iums), iran +98-2164352325, [email protected] saeid reza entezary department of anesthesiology and pain medicine,rasoul akram medical center, iran university of medical sciences (iums), iran +98-2164352325, [email protected] masood mohseni department of anesthesiology and pain medicine,rasoul akram medical center, iran university of medical sciences (iums), iran +98-2164352325, [email protected]

background several methods for assessment of severity of pain have been proposed but all of them are subjective. objectives this study evaluated the association concerning changes in electrical resistance (er) between two acupuncture points and severity of postoperative pain in order to define an objective measurement of pain. patients and methods in a cross-sectional study, 50 patients undergo...

2015
KENNETH S. COLE

Electrical impedance tomogram of the mammary gland (EIM). Seven planes of scanning. In the sixth and the seventh scans, a retromammary tissue is visualized. It can be used to distinguish tissues and identify pathologies. Lorentz force electrical impedance tomography is an ultrasoundbased medical imaging technique. In this study, a new platform based on electric cell-substrate impedance sensing ...

Journal: :Physics in medicine and biology 2015
Pol Grasland-Mongrain François Destrempes Jean-Martial Mari Rémi Souchon Stefan Catheline Jean-Yves Chapelon Cyril Lafon Guy Cloutier

Ultrasound speckle is a granular texture pattern appearing in ultrasound imaging. It can be used to distinguish tissues and identify pathologies. Lorentz force electrical impedance tomography is an ultrasound-based medical imaging technique of the tissue electrical conductivity. It is based on the application of an ultrasound wave in a medium placed in a magnetic field and on the measurement of...

2001
ERKKI SOMERSALO

In this article, the following electrical impedance tomography problem (EIT) is considered: On the surface of a body with unknown impedance distribution, one applies a set of prescribed electric currents and measures the corresponding voltages on the surface. From this information, one seeks to estimate the internal structure of the body. Potential application areas of the EIT range from medica...

Journal: :iranian journal of basic medical sciences 0
satish kumar department of physiology, yenepoya medical college, deralakatte, mangalore-575018. karnataka, india aswini dutt department of physiology, yenepoya medical college, deralakatte, mangalore-575018. karnataka, india sandhya hemraj department of radiology, yenepoya medical college, deralakatte, mangalore-575018. karnataka, india shankar bhat department of physiology, yenepoya medical college, deralakatte, mangalore-575018. karnataka, india bhat manipadybhima department of physiology, yenepoya medical college, deralakatte, mangalore-575018. karnataka, india

objective(s)bioelectrical impedance is the measure of impedance of the body. impedance consists of electric resistance and reactance. phase angle (pa) is the tan value of the ratio of reactance versus electric resistance. pa depends on cell membrane integrity and on body cell mass. there exists a correlation between pa values and body cell mass.the objective of this study was to compare the pa ...

Aswini Dutt Bhat Manipadybhima Sandhya Hemraj, Satish Kumar, Shankar Bhat

Objective(s)Bioelectrical impedance is the measure of impedance of the body. Impedance consists of electric resistance and reactance. Phase angle (PA) is the tan value of the ratio of reactance versus electric resistance. PA depends on cell membrane integrity and on body cell mass. There exists a correlation between PA values and body cell mass.The objective of this study was to compare the PA ...

Journal: :Physiological measurement 2015
Pascal O Gaggero Andy Adler Andreas D Waldmann Yasin Mamatjan Jörn Justiz Volker M Koch

An automated test system and procedure is proposed, designed to enable systematic testing of electrical impedance tomography (EIT) devices. The system is designed to calculate reliable, repeatable and accurate performance figures of merit of an EIT system using a saline phantom and an industrial robot arm. Applications of the test system are to compare EIT devices against requirements, or to he...

Journal: :Analytical chemistry 2016
Yixian Wang Xiaonan Shan Shaopeng Wang Nongjian Tao Pierre-Yves Blanchard Keke Hu Michael V Mirkin

We report on imaging of local electric field on an electrode surface with plasmonic electrochemical impedance microscopy (P-EIM). The local electric field is created by putting an electrode inside a micropipet positioned over the electrode and applying a voltage between the two electrodes. We show that the distribution of the surface charge as well as the local electric field at the electrode s...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید