نتایج جستجو برای: hydroxyapatite coating

تعداد نتایج: 46544  

In this study the bioactivity of hydroxyapatite/poly(ε-caprolactone)–poly(ethylene glycol) bilayer coatings on Nitinol superelastic alloy was investigated. The surface of Nitinol alloy was activated by a thermo-chemical treatment and hydroxyapatite coating was electrodeposited on the alloy, followed by applying the polymer coating. The surface morphology of coatings was studied using FE-SEM and...

2015
Yun-Lin Chen Tiao Lin An Liu Ming-Min Shi Bin Hu Zhong-li Shi Shi-Gui Yan

There are some arguments between the use of hydroxyapatite and porous coating. Some studies have shown that there is no difference between these two coatings in total hip arthroplasty (THA), while several other studies have shown that hydroxyapatite has advantages over the porous one. We have collected the studies in Pubmed, MEDLINE, EMBASE, and the Cochrane library from the earliest possible y...

Journal: :iranian journal of pharmaceutical sciences 0
aliasghar behnamghader materials and energy research center, tehran, iran, davood sharifi department of clinical sciences, surgery and radiology section, faculty of veterinary medicine, university of tehran, tehran-iran, sarang soroori department of clinical sciences, surgery and radiology section, faculty of veterinary medicine, university of tehran, tehran-iran, narjes bagheri materials and energy research center, tehran, iran, ranna tolouei department of biomedical engineering, science and research campus, islamic azad university, tehran, iran, roghieh nemati materials and energy research center, tehran, iran, denis najjar

in this study, hydroxyapatite was coated on titanium substrates by plasma spraying process. a well-known porous and lamellar microstructure was found in the lateral and outer surface of coating. the phase composition was studied by xrd and the morphological and the microstructural aspects were investigated by scanning electron and optical microscopy. the hardness of coatings and substrates was ...

2011
Surajit Mistry Debabrata Kundu Someswar Datta Debabrata Basu Chidambaram Soundrapandian

BACKGROUND The use of different bioactive materials as coating on dental implant to restore tooth function is a growing trend in modern Dentistry. In the present study, hydroxyapatite and the bioactive glass-coated implants were evaluated for their behavior in osseous tissue following implantation in 14 patients. MATERIALS AND METHODS Bioactive glass and hydroxyapatite formulated and prepared...

Journal: :iranian journal of pharmaceutical sciences 0
aliasghar behnamghader materials and energy research center, tehran, iran, narjes bagheri materials and energy research center, tehran, iran, babak raissi materials and energy research center, tehran, iran, ehsan marzbanrad materials and energy research center, tehran, iran, tahmineh forati department of biomedical engineering, islamic azad university, science and research branch, tehran, iran, dionysia ntentopoulou center of excellence in electrochemistry, faculty of chemistry, university of tehran, tehran, iran

the purpose of this study was to investigate the deposition of the hydroxyapatite (ha) coating via the electrophoresis procedure. the ha deposition was performed in an ethanol, methanol, acetone and isopropanol suspension. methanol was found to be the best deposition media. among the different environmental conditions, including the encapsulation of the samples under two vacuum types of pressur...

ژورنال: مجله دندانپزشکی 2014
شیرازی, هادی اصغرزاده , ملاک‌زاده, محمدرضا ,

  Background and Aims: Hydroxyapatite coating has allocated a special place in dentistry due to its biocompatibility and bioactivity. The purpose of this study was to evaluate the relation between the hydroxyapatite thickness and stress distribution by using finite element method.   Materials and Methods: In this paper, the effect of hydroxyapatite coating thickness on dental implants was studi...

Journal: :The Journal of bone and joint surgery. British volume 1998
I Onsten A Nordqvist A S Carlsson J Besjakov S Shott

In a single-blind, randomised series of knee replacements in 116 patients, we used radiostereometric analysis (RSA) to measure micromotion in three types of tibial implant fixation for two years after knee replacement. We compared hydroxyapatite-augmented porous coating, porous coating, and cemented fixation of the same design of tibial component. At one to two years, porous-coated implants mig...

Journal: :iranian journal of pharmaceutical sciences 0
hossein najafi department of materials science and engineering , sharif university of technology, tehran, iran, ziarat ali nemati department of materials science and engineering , sharif university of technology, tehran, iran, zahra sadeghianb oil research center, tehran, iran nafiseh sohrabi department of materials science and engineering , sharif university of technology, tehran, iran

this article describes the preparation and analysis of nano hydroxyapatite (ha) films on stainless steel 316l through sol-gel technique. the process started with preparation of a nitrate and phosphate sol. after aging the sol for 24 h at room temperature a ss316 substrate was dip-coated and heat-treated at 350 to 450 °c for different times in air. the coating phase and structure on substrate we...

2015
Valentyna Nosenko Nataliia Strutynska Igor Vorona Igor Zatovsky Volodymyr Dzhagan Sergiy Lemishko Matthias Epple Oleg Prymak Nikolai Baran Stanislav Ishchenko Nikolai Slobodyanik Yuriy Prylutskyy Nickolai Klyui Volodymyr Temchenko

Detonation-produced hydroxyapatite coatings were studied by scanning electron microscopy (SEM), X-ray powder diffraction (XRD), Raman spectroscopy, and electron paramagnetic resonance (EPR) spectroscopy. The source material for detonation spraying was a B-type carbonated hydroxyapatite powder. The coatings consisted of tetracalcium phosphate and apatite. The ratio depended slightly on the degre...

Journal: :The Journal of bone and joint surgery. British volume 2007
J-A Epinette M T Manley

This study describes 146 primary total knee replacements, either fully or partially coated with hydroxyapatite of which 74 knees in 68 patients were available for clinical and radiological assessment at a mean of 11.2 years (10 to 15). The global failure rate was 1.37% and survival rate with mechanical failure as the end-point was 98.14%. Radiological assessment indicated intimate contact betwe...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید