نتایج جستجو برای: intramedullary limb lengthening

تعداد نتایج: 82262  

Journal: :archives of trauma research 0
ulrich wiebking department of trauma, medical school hannover, hannover, germany; department of trauma, medical school hannover, hannover, germany. tel: +49-5115322050, fax: +49-5115325877 emmanouil liodakis department of trauma, medical school hannover, hannover, germany mohamed kenawey department of orthopedic surgery, sohag university, sohag, egypt christian krettek department of trauma, medical school hannover, hannover, germany

conclusions we report of loss of achieved length after lengthening with a telescopic nail. weight bearing before complete consolidation of the regenerate might be a risk factor for that. thorough examination of the limb length and careful evaluation of the radiographs are required in the follow-up period. the precice nail system requires the same vigilance like the other intramedullary systems ...

Journal: :trauma monthly 0
haci bayram tosun department of orthopaedics and traumatology, faculty of medicine, adiyaman university, adiyaman, turkey; department of orthopaedics and traumatology, faculty of medicine, adiyaman university, adiyaman, turkey. tel: +90-5334497699, fax: +90-4162231693 ismail agir department of orthopaedics and traumatology, faculty of medicine, adiyaman university, adiyaman, turkey seyitali gumustas department of orthopaedics and traumatology, faculty of medicine, adiyaman university, adiyaman, turkey sancar serbest department of orthopaedics and traumatology, faculty of medicine, kirikkale university, kirikkale, turkey abuzer uludag department of orthopaedics and traumatology, faculty of medicine, adiyaman university, adiyaman, turkey suat celik department of orthopaedics and traumatology, faculty of medicine, adiyaman university, adiyaman, turkey

conclusions the fixator-assisted lengthening plate technique helps to maintain the stability and alignment at both sides of an osteotomy during tibial elongation. it allows the early removal of the external fixator immediately after lengthening is completed. this technique can be applied in children with open physes and in patients with a narrow medullary canal who are unsuitable for limb lengt...

Journal: :Orthopedics 2014
Rishi Thakral Aaron J Johnson Stacy C Specht Janet D Conway Kimona Issa Michael A Mont John E Herzenberg

Limb-length discrepancy after total hip arthroplasty (THA) leads to patient dissatisfaction and can be a cause of orthopedic surgery malpractice cases. Nonsurgical and surgical techniques exist to correct limb-length discrepancies. Two limb-lengthening methods were used to correct greater than 2-cm limb-length discrepancies after THA: lengthening over a femoral nail with an external fixator and...

Journal: :Journal of applied biomechanics 2011
Rolf D Burghardt John E Herzenberg Manfred H Burghardt

Femoral lengthening with intramedullary nails can create alterations in the mechanical axis of the limb. This is based on the relationship of the anatomic femur axis to the mechanical femur axis, which is typically 5-9 degrees valgus. We developed trigonometric formulas to calculate the predicted change, using the lengths of the tibia, femur, and whole limb; the amount of lengthening; and the a...

Journal: :Expert review of medical devices 2015
Dror Paley

The PRECICE(®) Intramedullary Limb Lengthening System (Ellipse Technologies Inc., CA, USA) is a remotely controlled, magnetically driven, implantable limb lengthening intramedullary nail system. It has both CE mark and US FDA clearance for its first- (2011) and second-generation (2013) implants. It is indicated for the treatment of limb length discrepancy and short stature. It has been used wor...

Journal: :Strategies in Trauma and Limb Reconstruction 2020

Journal: :The Journal of bone and joint surgery. British volume 2012
R D Burghardt D Paley S C Specht J E Herzenberg

Internal lengthening devices in the femur lengthen along the anatomical axis, potentially creating lateral shift of the mechanical axis. We aimed to determine whether femoral lengthening along the anatomical axis has an inadvertent effect on lower limb alignment. Isolated femoral lengthening using the Intramedullary Skeletal Kinetic Distractor was performed in 27 femora in 24 patients...

2017
Mitchell Bernstein

Limb equalization using the Ilizarov method has evolved and adapted the use of internal lengthening devices. One of the newest devices, termed "PRECICE," is a magnetically controlled telescoping nail. Complications such as pin site infection and skin irritation are eliminated. Despite trauma surgeons' familiarity with intramedullary nailing, the Ilizarov method requires sound knowledge of defor...

2017
Todd A. Kuiken Bennet A. Butler Tom Sharkey Andre D. Ivy Daniel Li Terrance D. Peabody

BACKGROUND Lower limb loss is a highly disabling medical condition that can severely impact a person's quality of life. Recovery becomes especially challenging if an amputee has a short residual limb, which can complicate proper prosthetic fitting, causing discomfort, difficulties in suspension, and reduced mobility. Current limb lengthening techniques such as the Ilizarov apparatus and externa...

2016
Haci Bayram Tosun Sancar Serbest Abuzer Uludag Seyitali Gumustas Suat Celik

There are many techniques for limb lengthening. Lengthening over a plate is an alternative choice of fixation in children or when nailing is difficult. We present a new technique for tibial lengthening with using a monolateral external fixator over a lengthening plate.Lengthening over an intramedullary nail is a commonly used method in patients with short stature or limb-length discrepancy. How...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید