نتایج جستجو برای: laser fluorimetry
تعداد نتایج: 184158 فیلتر نتایج به سال:
[no abstract available]
Highly sensitive techniques are needed for the quantitative determination of mitochondrial oxidative phosphorylation function in single rat hippocampal slices or isolated hippocampal subfields. We determined the oxygen consumption of single hippocampal slices or subfields applying high-resolution respirometry adapted for slice measurements and measured the redox state of mitochondrial NAD(P)H i...
Laser-induced fluorescence (LIF) is examined as a sensitive and selective detector for microcolumn liquid chromatography (LC). This detector employs a cw helium-cadmium laser (325 nm, 5-10 mW) as the excitation source together with a simple filter/ photomultiplier optical system. Several flowcells are evaluated: (1) a flowing droplet; (2) an ensheathed effluent stream; and (3) a fused-silica ca...
Background: Measurement of back ground concentration of uranium in drinking water is very important for many reasons, specially, for human health. The uranium concentration in drinking water in many counties is a matter of concern for clinical and radioactive poisoning. Materials and Methods: The uranium concentration in drinking water is determined using laser flourimatric uranium analyzer. Fo...
By combining laser fluorimetry with high pressure liquid chromatography, we are able to detect and quantitate the naturally fluorescent mycotoxin, zearalenone, in contaminated corn samples. Experiments with zearalenone standards show a linear fluorimeter response over four orders of magnitude with a detection limit of 300 pg zearalenone injected onto a C,8 reverse phase column. The corn samples...
background: measurement of back ground concentration of uranium in drinking water is very important for many reasons, specially, for human health. the uranium concentration in drinking water in many counties is a matter of concern for clinical and radioactive poisoning. materials and methods: the uranium concentration in drinking water is determined using laser flourimatric uranium analyzer. fo...
any change in the refractive index of a laser active medium can lead to serious degradation of beam quality, laser beam modes, laser performance and variation in the intensity distribution. alteration in the refractive index of laser active medium is especially notable in high power lasers. it is clear that in the laser beam production, the pumping agent induces a great amount of heat which...
Protein instability is a major obstacle in the production and delivery of monoclonal antibody-based therapies for cancer. This study presents real-time isothermal differential scanning fluorimetry as an emerging method to evaluate the stability of human immunoglobulin G protein with high sensitivity. The stability of polyclonal human immunoglobulin G against urea-induced denaturation was assess...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید