نتایج جستجو برای: mtwo

تعداد نتایج: 232  

2012
Shahriar Shahi Hadi Mokhtari Saeed Rahimi Vahab Shiezadeh Habib Ashasi Majid Abdolrahimi Mohammad Foroughreyhani

AIM The aim of the present study was to electrochemically evaluate corrosion resistance of RaCe and Mtwo files after repeated sterilization and preparation procedures. STUDY DESIGN A total of 450 rotary files were used. In the working groups, 72 files from each file type were distributed into 4 groups. RaCe and Mtwo files were used to prepare one root canal of the mesial root of extracted hum...

Journal: :International endodontic journal 2006
E Schäfer M Erler T Dammaschke

AIM To compare the shaping ability of Mtwo instruments with K3 and RaCe instruments. Part 1 of this two-part report describes the efficacy of these nickel-titanium instruments in simulated curved root canals. METHODOLOGY Simulated canals with 28 degree and 35 degree curves in resin blocks were prepared with Mtwo instruments using a single length technique and with K3 and RaCe instruments usin...

2010
Hasan Ramzi Noushin Shokouhinejad Mohammad Ali Saghiri Ardavan Samieefard

INTRODUCTION The purpose of this study was to evaluate the efficacy of three methods in removal of Resilon/new Epiphany self-etch (SE) soft resin endodontic obturation system. MATERIALS AND METHODS Thirty extracted single rooted human teeth were prepared for endodontic treatment and obturated with Resilon/Epiphany SE. The roots were randomly divided into three groups; group 1 roots were retre...

Journal: :Australian endodontic journal : the journal of the Australian Society of Endodontology Inc 2014
Emre Iriboz Hesna Sazak Öveçoğlu

To evaluate the effectiveness of the ProTaper and Mtwo retreatment systems for removal of resin-based obturation techniques during retreatment. A total of 160 maxillary anterior teeth were enlarged to size 30 using ProTaper and Mtwo rotary instruments. Teeth were randomly divided into eight groups. Resilon + Epiphany, gutta-percha + Epiphany, gutta-percha + AH Plus and gutta-percha + Kerr Pulp ...

Journal: :Journal of clinical and diagnostic research : JCDR 2015
Akansha Garg Ajay Nagpal Shashit Shetty Sunil Kumar Kamal Krishan Singh Amit Garg

INTRODUCTION To evaluate and compare the amount of time required by three rotary NiTi instruments in removing gutta-percha from root canal during retreatment with hand file as control. MATERIALS AND METHODS Eighty human mandibular premolars with single straight root canals were prepared and obturated by cold lateral condensation with gutta-percha and AH Plus sealer. After two weeks, the 80 te...

2014
Diogo Silva Aline Cristine Gomes Juliana Melo da Silva Aline de Almeida Neves Alexandre Augusto Zaia

Aim: To evaluate the foraminal transportation during foraminal enlargement after manual instrumentation with stainless steel files, preparation with the Mtwo system and Reciproc R25 file. Methods: Thirty roots were selected, divided in three groups and prepared in accordance with the different instrumentation systems: Hand Files (HF); Mtwo system (MS); and Reciproc system (RS). All groups were ...

Journal: :International endodontic journal 2014
S Bürklein L Börjes E Schäfer

AIM To compare the shaping ability of three different nickel-titanium rotary instruments during the preparation of curved root canals in extracted teeth. METHODOLOGY A total of 60 root canals with curvatures ranging between 25° and 35° were divided into three groups of 20 canals. Based on radiographs taken prior to instrumentation, the groups were balanced with respect to the angle and the ra...

Journal: :International endodontic journal 2006
E Schäfer M Erler T Dammaschke

AIM To compare the cleaning effectiveness and shaping ability of Mtwo, K3, and RaCe nickel-titanium rotary instruments during the preparation of curved root canals in extracted human teeth. METHODOLOGY A total of 60 root canals of mandibular and maxillary molars with curvatures ranging between 25 degrees and 35 degrees were divided into three groups of 20 canals. Based on radiographs taken pr...

2012
Hengameh Akhavan Yaser Khalil Azdadi Shahram Azimi Bahare Dadresanfar Anahid Ahmadi

INTRODUCTION Retreatment is performed in teeth with unsuccessful root canal therapy or persistent apical lesion. The most important factor for achieving successful retreatment is thorough cleaning and reshaping. NiTi files and rotary instruments are widely used for the removal of obturatants. This study compared the ability of Mtwo and D-RaCe retreatment systems to remove residual gutta-percha ...

2014
Hadi Mokhtari Mahdi Niknami Aydin Sohrabi Ehsan Habibivand Hamid Reza Mokhtari Zonouzi Saeed Rahimi Vahid Zand

INTRODUCTION The aim of this in vitro study was to evaluate the transportation of mesiobuccal canals of mandibular first molars prepared with either BioRaCe or Mtwo rotary instruments or hand K-Flexofile, by means of cone-beam computed tomography (CBCT). METHODS AND MATERIALS Forty-five mandibular molars were selected and randomly divided into three groups (n=15). Mesiobuccal roots of these t...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید