نتایج جستجو برای: neelsen

تعداد نتایج: 1015  

ژورنال: پژوهش در پزشکی 2013
آقا ملایی, سمیه, ابدی, علیرضا, تحویلدار بیدرونی, فرید, تقی پور, نیلوفر, حقیقی, علی, صالحی, نیما,

Abstract Background: Usual diagnostic methods for detection of Cryptosporidium include smear preparation, modified Zeihl-Neelsen staining, microscopic examination and observation of oocysts. No studies have been done to compare PCR and Zeihl-Neelsen staining in Iran. This study was done to determine the positive predictive value, (PPV) and the negative predictive value (NPV) of PCR in compariso...

2017
Meseret Workineh Mandie Maru Ibrahim Seman Ziyadu Bezu Markos Negash Mulugeta Melku Addisu Gize Agumas Shibabaw

Background The sensitivity of smear microscopy for diagnosis of tuberculosis might be improved through treatment of sputum with sodium hypochlorite and application of fluorescent microscopy. This study aimed to determine the agreement between direct Fluorescent Microscopy and Ziehl-Neelsen concentration technique by their ability of detecting acid fast bacilli in resource poor settings. Metho...

Journal: :Journal of clinical pathology 1994
A Rattan K Kishore S Singh M Jaber I Xess R Kumar

AIMS To evaluate a safe sputum processing method for detection of tuberculosis in developing countries. METHODS A sample processing method was developed in which acid fast bacilli were killed with 1% sodium hypochlorite and concentrated by flotation on a layer of xylene before staining by the Ziehl Neelsen or auramine O methods. RESULTS Best results were obtained by auramine O staining afte...

2016
Mir Attaullah Khan Shagufta Nasir Pervez Shafi Ullah Khan Ali Khan

Background: Lymph node tuberculosis (LNTB) is the leading form of extra pulmonary tuberculosis and common in our country. Acid Fast Bacilli (AFB) detection by Ziehl-Neelsen (ZN) method in the fine needle aspirate from these lymph nodes is confirmatory. Objective: To assess the diagnostic utility of Ziehl-Neelsen staining in lymphadenopathy cases, since it is commonly used method in the diagnosi...

2007
Nada F. Al-Rawi

The presence of acid fast bacilli in sputum specimen was investigated comparatively with Ziehl-Neelsen (ZN)and Kinyoun Cold staining (KC) in order to determine sensitivity in detecting Tuberculosis Bacilli (T.B.). This study was employed on patients with severe lower respiratory tract infection to compare between these two stains. Which revealed that Ziehl-Neelsen procedure gives better results...

Journal: :JPMA. The Journal of the Pakistan Medical Association 2018
Komal Shakeel Shagufta Iram Mehwish Akhtar Shahida Hussain Hannana Maryam Ambreen Anwar

OBJECTIVE To evaluate the performance of GeneXpert for detection of mycobacterium tuberculosis in pus samples and compare its results with conventional techniques in terms of validity, rapidity and rifampicin resistance. METHODS This longitudinal, descriptive study was conducted at Jinnah Hospital, Lahore, Pakistan, from January 2012 to December 2015, and comprised pus samples of people suspe...

Journal: :archives of clinical infectious diseases 0
masood ziaee department of microbiology, birjand university of medical sciences, birjand, ir iran; department of microbiology, birjand university of medical sciences, birjand, ir iran. email: mohammad namaei department of microbiology, birjand university of medical sciences, birjand, ir iran majid khazaei department of physiology, isfahan university of medical sciences, isfahan, ir iran ghodsieh azarkar department of microbiology, birjand university of medical sciences, birjand, ir iran

conclusion fm is more sensitive than zn for diagnosis of tb. however, since fm is more sensitive and rapid, using this method in clinical laboratories with large specimen numbers is recommended. results a total of 102 out of 920 study subjects had pulmonary tb, of them 68 (66.66%) patients were smear positive by either staining method while others were smear negative. the proportion of positive...

Journal: :The American journal of tropical medicine and hygiene 2010
Leopold G Lehman Arlette L Ngapmen Yamadji Françoise Ngo Sack Charles F Bilong Bilong

Poor laboratory equipment and few human resources have made it difficult to implement microscopic diagnosis of pulmonary tuberculosis (TB) on a large scale basis worldwide. Three hundred sputum samples from patients in Cameroon were studied by using the CyScope®, a new light-emitting, diode-based, fluorescence microscope, to compare auramine-rhodamine fluorescence with the conventional Ziehl-Ne...

2013
Brijesh Thakur Ravi Mehrotra Jitendra Singh Nigam

Objective. To study the correlation of cytomorphological features in fine needle aspiration smears from patients suspected of having tuberculous lymphadenitis with Ziehl-Neelsen staining (ZN), auramine-rhodamine staining (ARS), and autofluorescence (AF). Methods. A total of 145 lymph nodes were aspirated, 3 air-dried smears were stained with Giemsa, Ziehl-Neelsen, and auramine-rhodamine stains,...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید