نتایج جستجو برای: normalized glandular dose

تعداد نتایج: 361738  

Mahdi Ghorbanee Mohamad reza Deevband Zeinab Kave

Introduction: Average glandular dose (AGD), entrance skin air kerma (ESAK) and normalized glandular dose (DgN) are the main dosimetric quantities in mammography. In this study, DgN is evaluated in the presence of breast cyst, which is a common disease among women and the influence of size, number and location of the cysts on the DgN is investigated. Materials and Meth...

Journal: :Journal of radiation research 2010
Khatayut Nigapruke Patana Puwanich Nakorn Phaisangittisakul Wiwat Youngdee

This study aims to determine the average absorbed dose of radiation in glandular tissue during mammography and to investigate factors that influence the average glandular dose, particularly the local distribution of glandular tissue within the breast and breast skin thickness. An EGSnrc Monte Carlo code and associated codes were employed in the simulation. The breast voxel models used consist o...

ژورنال: پژوهش در پزشکی 2018

Background: Average glandular dose (AGD), entrance skin air kerma (ESAK) and normalized glandular dose (DgN) are the main dosimetric quantities in mammography. Breast tissue composition is one of the factors affecting on DgN values. In this study both homogeneous and heterogeneous breast tissue is assumed and its impact on DgN values are evaluated. Methods: Homogeneous breast phantom with diffe...

2008
Ioannis Sechopoulosa Carl J. D'Orsi

With the advent of new detector technology, digital tomosynthesis imaging of the breast has, in the past few years, become a technique intensely investigated as a replacement for planar mammography. As with all other x-ray-based imaging methods, radiation dose is of utmost concern in the development of this new imaging technology. For virtually all development and optimization studies, knowledg...

2010
Vagner Ferreira Cassola Gabriela Hoff

OBJECTIVE: To compare data regarding dosimetry and photons fluence in different breast phantoms, discussing constancy tests and dosimetry applied to mammography. MATERIALS AND METHODS: Different homogeneous breast phantoms and one anthropomorphic voxel phantom were developed for collection of data regarding total absorbed dose in the phantom, absorbed dose in the glandular tissue material-equiv...

Journal: :Physics in medicine and biology 2016
G Mettivier C Fedon F Di Lillo R Longo A Sarno G Tromba P Russo

The purpose of this work is to provide an evaluation of the mean glandular dose (MGD) for breast computed tomography (CT) with synchrotron radiation in an axial scanning configuration with a partial or total organ volume irradiation, for the in vivo program of breast CT ongoing at the ELETTRA facility (Trieste, Italy). A Geant4 Monte Carlo code was implemented, simulating the photon irradiation...

2010

ID: 12899 Title: Dosimetric Characterization of a Dedicated Breast Computed Tomography Clinical Prototype System Purpose: To determine the radiation dosimetry characteristics of a dedicated breast computed tomography (BCT) clinical prototype system. Method and Materials: The relevant parameters of the BCT system were replicated in a Monte Carlo simulation program based on the Geant4 toolkit. To...

Journal: :iranian journal of medical physics 0
a. a. mowlavi assistant professor, physics dept., school of sciences, tarbiat moallem university of sabzevar, sabzevar, iran.

introduction: to write a computational program to calculate the average glandular dose in mammography with rh-rh target-filter and also use it as an accurate and fast method of dose calculation founder different situations. materials and methods: in this research, the sobol-wu parameters are used to write a fortran code for glandular dose calculation in rh-rh target-filter mammograms. the code ...

Journal: :iranian journal of radiation research 0
m.b. tavakoli department of medical physics and medical engineering, isfahan university of medical sciences, isfahan, iran n. kolghi department of medical physics and medical engineering, isfahan university of medical sciences, isfahan, iran z. shahi department of medical physics and medical engineering, isfahan university of medical sciences, isfahan, iran z. shaneh department of medical physics and medical engineering, isfahan university of medical sciences, isfahan, iran

background: breast is one of the main radiological sensitive organs, hence it is important to evaluate absorbed dose to this organ especially to the glandular parts. it is the aim of this study to measure mean glandular dose and image contrast in terms of different mammographic parameters. materials and methods: in this study two mammography machines located at said-al shohada (giotto) and shah...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید