نتایج جستجو برای: patient dose

تعداد نتایج: 982524  

Journal: :iranian journal of medical physics 0
asghar mesbahi assistant professor, medical physics dept., tabriz university of medical sciences, tabriz, iran. radiotherapy physicist of the radiotherapy department of imam hospital, tabriz, iran. naser aslanabadi associate professor, cardiology dept., tabriz university of medical sciences, tabriz, iran. parinaz mehnati associate professor, medical physics dept., tabriz university of medical sciences, tabriz, iran. ahmad keshtkar associate professor, medical physics dept., tabriz university of medical sciences, tabriz, iran.

introduction: coronary angiography and angioplasty procedures lead to significant radiation exposure of patients. in the current study, the average radiation dose to patients during angiography in the angiography department of shahid-madani hospital was determined. materials and methods: an image intensifier based angiography unit (philips bh 3000) was used for angiography procedures. the accur...

Journal: :iranian journal of medical physics 0
t. sadeghyani m. sc. in medical physics, medical physics dept., tarbiat modarres university, tehran, iran. b. hashemi malayeri assistant professor, medical physics dept., tarbiat modarres university, tehran, iran. h. hashemi assistant professor, radiology dept., imam khomeini hospital, tehran, iran. a.a. sharafi associate professor, radiology dept., iran medical sciences university, tehran, iran.

introduction: in 2000, the unscear reported that ct constitutes 5% of all the medical x-ray  examinations and it contributes 34% of the resultant collective dose worldwide. children are more  sensitive to the ionizing radiations than adults. so, routine quality control tests are expected to be  carried out periodically on the ct scanners. the aim of this research was to estimate the effective  ...

Journal: :iranian journal of radiation research 0
f. bouzarjomehri department of medical physics, shahid sadooghi university of medical sciences, yazd, iran v. tsapaki department of medical physics, konstantopoulio hospital, nea ionia, athens, greece

background: the number of interventional cardiology (ic) procedures has increased rapidly. coronary angiography (ca) and percutaneous transluminal coronary angioplasty (ptca) are now widely performed as a matter of routine, and they are considered safe procedures for experienced cardiologists. however, it is also known that these procedures are associated with high radiation doses due to long f...

Journal: :iranian journal of radiation research 0
f. bouzarjomehri health physics dept. shahid sadoghi univ. of medical sciences, yazd, iran

background: medical x-rays are the largest man-made source of public exposure to ionizing radiation. it is important to avoid conditions where the amount of radiation used is more than that needed for the procedure. materials and methods: the entrance skin exposure (ese) measurement was conducted for quality control of x-ray machines and survey of operator’s experimental techniques. the eses we...

Journal: :iranian journal of radiation research 0
f. bouzarjomehri department of medical physics, shahid sadoghi university of medical sciences, yazd, iran m. h. zare department of medical physics, isfahan university of medical sciences, isfahan, iran d. shahbazi department of medical physics, isfahan university of medical sciences, isfahan, iran

abstract   background: while the benefits of computed tomography (ct) are well known in accurate diagnosis, those benefits are not risk free. ct is a device with higher patient dose in comparison with other conventional radiological procedures. is the reduction of exposures by requiring optimization of ct procedures [a principle concern in radiological protection]? in this study, the radiation ...

Journal: :iranian journal of radiation research 0
s.m. ghavami radiology department, paramedical school, tabriz university of medical sciences, tabriz, iran a. mesbahi medical physics department, medical school, tabriz university of medical sciences, tabriz, iran i. pesianian radiology department, paramedical school, tabriz university of medical sciences, tabriz, iran

background: x-ray computed tomography (ct) examinations deliver a significant amount of radiation doses to patients comparing to conventional radiography examinations. the objective of the current study was to analyze and investigate the average patient received dose from axial and spiral ct exams in a medical imaging center. material and methods: in this study, the patient imaging technique, w...

Journal: :journal of paramedical sciences 0
fariba firouzi department of radiology, shahidbeheshti university of medical sciences, tehran, iran soraya emamgholizadeh minaei department of radiology, shahidbeheshti university of medical sciences, tehran, iran hamid reza khosravi nuclear and radiation support department, iranian nuclear regulatory authority, tehran, iran

medical x-rays are the largest man-made source of public exposure to ionizing radiation. while the benefits of computed tomography (ct) are well known in accurate diagnosis, those benefits are not risk free. ct is a device with higher patient dose in comparison with other conventional radiation procedures. so it is important to avoid conditions where the amount of radiation used is more than th...

Journal: :journal of paramedical sciences 0
soraya emamgholizadeh minaei department of radiology, shahid beheshti university of medical sciences, tehran, iran fariba firouzi department of radiology, shahid beheshti university of medical sciences, tehran, iran hamid reza khosravi nuclear and radiation support department, iranian nuclear regulatory authority, tehran, iran

this study was a part of national project to establish and optimize local and national diagnostic guidance levels. this work intends to evaluate image quality and entrance surface air kerma (esak) for patients' radiographic examinations in two north western provinces of country. two hospitals got involved in the present study. the rate of the rejected images and image quality grades were determ...

Journal: :iranian journal of radiation research 0
m. gholami department of medical physics and radiation sciences, faculty of allied medical sciences, lorestan university of medical sciences, khorram abad, iran a. maziar department of medical physics and medical engineering, faculty of medicine, isfahan university of medical sciences, isfahan, iran h.r. khosravi atomic energy organization of iran, tehran, iran f. ebrahimzadeh department of biostatistics, faculty of health & nutrition, lorestan university of medical sciences, khorram abad, iran s. mayahi department of medical physics and radiation sciences, faculty of allied medical sciences, lorestan university of medical sciences, khorram abad, iran

background: in diagnostic radiology there are two reasons for measuring or estimating radiation doses to patients. firstly measurements provide a means for setting and checking standards of good practice as an aid to the optimization of patient protection. secondly estimates of the absorbed dose to tissue and organs in the patients. materials and methods: a total of 2382 patients were studied t...

Journal: :iranian journal of radiation research 0
gh.r. fallah mohammadi1 department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, ira n. riyahi alam department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, ira gh. geraily department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, ira r. paydar radiation sciences department, faculty of allied medicine, iran university of medical sciences, tehran, iran

background:  this study presents patient specific and organ dose estimation in computed tomography (ct) imaging of thorax directly from patient ct image using monte carlo simulation.  patient's ct image is considered as the patient specific phantom and the best representative of patient physical index in order to calculate specific organ dose. materials and methods: egsnrc /beamnrc monte c...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید