Journal: :Chemosphere 2004
Nicola Verdone Paolo De Filippis

The dry treatment of flue gas produced by incineration processes is discussed thermodynamically. The study investigates the theoretical limits achieved by sodium and calcium based sorbents in the removal of the pollutant species HCl, NOx and SO2. Calculations were performed varying the temperature and the molar ratio between the amount of the injected alkaline sorbent and the content of the pol...

ترابی, لیلا, صیدمحمدی, عبدالمطلب, عسگری, قربان,

Background and purpose: Metronidazole is a serious environmental pollutant due to high consumption and persistence in biological degradation. This study aimed at removal of metronidazole using ozone (O3) activated persulfate (PS) in presence of ultrasound (US). Materials and methods: A laboratory scale study was carried out in batch reactor using US irradiation and O3 generator apparatuses. ...

Journal: :Journal of environmental management 2009
Mohammad M Emamjomeh Muttucumaru Sivakumar

The word "electrocoagulation" (EC) will be sometimes used with "electroflotation" (EF) and can be considered as the electrocoagulation/flotation (ECF) process. Through the process of electrolysis, coagulating agents such as metal hydroxides are produced. When aluminium electrodes are used, the aluminium dissolves at the anode and hydrogen gas is released at the cathode. The coagulating agent co...

2016
M. M. R. Jahangir K. G. Richards M. G. Healy L. Gill C. Müller P. Johnston

The removal efficiency of carbon (C) and nitrogen (N) in constructed wetlands (CWs) is very inconsistent and frequently does not reveal whether the removal processes are due to physical attenuation or whether the different species have been transformed to other reactive forms. Previous research on nutrient removal in CWs did not consider the dynamics of pollution swapping (the increase of one p...

Journal: :environmental health engineering and management 0
amirreza talaiekhozani civil engineering department, jami institute of technology, isfahan, iran zeinab eskandari chemical engineering department, jami institute of technology, isfahan, iran mohammad reza talaei chemical engineering department, shiraz university, shiraz, iran malihe salari civil engineering department, jami institute of technology, isfahan, iran

background: in this study, ferrate (vi) and ultraviolet (uv) radiation were employed to remove hydrogen sulfide from municipal wastewater resulting in a reduction in chemical oxygen demand (cod). although ferrate (vi) and uv have been used individually for the removal of a few pollutants from urban and industrial wastewater, there exists no study to investigate the effectiveness of simultaneous...

2015
C. L. Heald D. Cooley W. C. Porter B. Russell

The MIT Faculty has made this article openly available. Please share how this access benefits you. Your story matters. Abstract. Air pollution variability is strongly dependent on meteorology. However, quantifying the impacts of changes in regional climatology on pollution extremes can be difficult due to the many non-linear and competing meteorological influences on the production, transport, ...

2012
M. E. Ersahin J. B. Gimenez H. Ozgun

A laboratory scale external anaerobic dynamic membrane bioreactor (AnDMBR) treating high strength wastewater was operated to assess the effect of gas sparging velocity and organic loading rate on removal efficiency and dynamic membrane (DM) filtration characteristics. An increase in gas sparging velocity (GSV) results in a decrease in DM filtration resistance. DM or cake formation was identifie...

2006
M. A. Aboulhassan S. Souabi A. Yaacoubi M. Baudu

Surfactants are among the most widely disseminated xenobiotics that contribute significantly to the pollution profile of sewage and wastewaters of all kinds. Among the currently employed chemical unit processes in the treatment of wastewaters, coagulation-flocculation has received considerable attention for yielding high pollutant removal efficiency. Jar-test experiments are employed in order t...

Background; The aim of this study is to compare UV, ferrate (VI) and UV/ferrate (VI) methods for removal of hydrogen sulfide and chemical oxygen demand (COD) from municipal wastewater under a continuous condition. Methods; The experiment was divided into three parts: 1) pollutants removal by using ferrate (VI) alone; 2) pollutants removal using UV alone; 3) pollutants removal using a combina...

Journal: :Water environment research : a research publication of the Water Environment Federation 2008
John R Middleton Michael E Barrett

The objective of this research was to modify an extended detention basin to provide batch treatment of stormwater runoff. An automated valve/controller was developed and placed on the outlet of a detention basin in Austin, Texas, which allowed the water quality volume to be retained in the basin for a preset length of time. The influent and effluent of the modified basin were monitored for tota...