نتایج جستجو برای: polymer gel

تعداد نتایج: 194035  

R. Jafari Khalilabadi, S. Aftabi, S.M. Abtahi,

Background: There are various methods to read out responses of a polymer-gel dosimeter, among which the Magnetic Resonance Imaging (MRI) technique is the most common one. Optimizing imaging protocols can have significant effect on the sensitivity and the dose resolution of polymer gel dosimeters. This study has investigated the effects of the number of echoes (NOE) and the echo time spacing (ES...

Journal: :iranian journal of medical physics 0
azizollah rahimi msc student of medical physics, tarbiat modares university, tehran, iran. bijan hashemi associate professor, medical physics dept., tarbiat modares university, tehran, iran. mohammad hassan zahmatkesh assistant professor, novin medical radiation institute, tehran, iran. ramin jaberi physicist, cancer institute, department of radiotherapy and oncology, imam khomeini hospital, tehran, iran. shahab sheibani assistant professor, nuclear sciences research center, nuclear science and technology research center, tehran, iran.

introduction: polymer gels are modern dosimeters providing three dimensional dose distributions. these dosimeters can be used in brachytherapy in which the tumor dimension is relatively small and the dose gradient is high. in this study, the ability of the magica polymer gel was investigated for assessing the absolute dose values as well as the dose distribution of low dose rate (ldr) ir-192 wi...

Journal: :iranian journal of medical physics 0
asghar mesbahi medical physics department, faculty of medicine, tabriz university of medical sciences, tabriz, iran. radiation oncology department, imam hospital, tabriz, iran

introduction the purpose of the current study was to determine optical sensitivity of n-isopropyl acrylamide nipam and polyacrylamide gelatin and tetrakis hydroxymethyl phosphoniun chloride (pagat) polymer gels for different wavelength of visible light spectrum applied in optical computed tomography method. materials and methods nipam and pagat polymer gels with conventional formulations used f...

Journal: :iranian journal of medical physics 0
hadis ansari mehr1 department of medical radiation engineering, science and research branch, islamic azad university, tehran, iran

introduction the use of cut-outs in electron applicators make changes on output, isodose, and percentage depth dose (pdd) curves. these changes and electron beam dose distribution in the form of three-dimensional (3d) can be measured by gel dosimeters. materials and methods dosimetry was performed with and without a square shield (6×6 cm2 field). the energies were 4, 9, and 16 mev and phantom w...

Seyed Mohammad Mahdi Abtahi Vahid Anaraki

Introduction: Three physical conditions caused an external beam designated as a small field. The first is the loss of lateral charged particle equilibrium. The second is the effect of collimators on the primary photon source occlusion. The third condition is the size of the detector which is large compared to the field size. The most obvious perturbation effects in last condit...

Excessive water production through fractures become an important problem in oil exploration of fractured reservoirs. For this purpose, polymer gels were prepared by crosslinking of aqueous solutions of polymer and crosslinker for the purpose of water management in high water cut fractured reservoirs. A copolymer of sulfonated polyacrylamide was used as polymer and chromium triacetate (Cr(OA...

Journal: :iranian journal of radiation research 0
a.r. farajollahi department of medical physics, faculty of medicine, tabriz university of medical sciences, tabriz, iran f. pak department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, iran m. horsfield department of cardiovascular sciences, university of leicester, leicester royal infirmary, leicester, uk z. myabi department of radiology, emam reza teaching hospital, tabriz university of medical sciences, tabriz, iran

background: in this study the basic radiation properties of n-isopropylacrylamaide polymer gel dosimeter were determined together with verification of its soft tissue equivalency. materials and methods: the nipam gel was prepared and irradiated approximately 2 h after manufacturing. the magnetic resonance (mr) images were made 24 h after irradiation. the nuclear magnetic resonance (nmr) respons...

Journal: :iranian journal of radiation research 0
k. adinehvand borujerd islamic azad university, borujerd, iran m.h. zahmatkesh novin radiation medicine institute, tehran, iran m.r aghamiri division of radiation medicine, shahid beheshti university, tehran, iran sh. akhlaghpour department of radiology, tehran university of medical sciences, tehran, iran s. bagheri novin radiation medicine institute, tehran, iran

background: the purpose of this study was to evaluate the dependency of magica polymer gel dosimeter response (r2) on different electron energies as well as on different mean dose rate for a standard clinically used linear accelerator. materials and methods: the sensitivity of the dosimeter was represented by the slope of calibration curve in the linear region measured for each modality. a cali...

A.R. Farajollahi, F. Pak, M. Horsfield, Z. Myabi,

Background: In this study the basic radiation properties of N-isopropylacrylamaide polymer gel dosimeter were determined together with verification of its soft tissue equivalency. Materials and Methods: The NIPAM gel was prepared and irradiated approximately 2 h after manufacturing. The magnetic resonance (MR) images were made 24 h after irradiation. The nuclear magnetic resonance (NMR) respons...

Journal: :iranian journal of chemistry and chemical engineering (ijcce) 2007
mohammad simjoo mohsen vafaie sefti ahmad dadvand koohi reza hasheminasab valiahmad sajadian

in this paper, polyacrylamide/chromium acetate gel polymer system was prepared as water shut-off system to control water production in one of the iranian oil reservoirs condition. effect of various parameters such as temperature (90 °c) and water formation from view point of salinity and divalent cations, was evaluated on the gelation kinetic and gel strength using bottle testing method. the re...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید