نتایج جستجو برای: polytetrafluoroethylene

تعداد نتایج: 2980  

Journal: :Biomaterials 1991
A Dekker K Reitsma T Beugeling A Bantjes J Feijen W G van Aken

From in vitro experiments it is known that human endothelial cells show poor adhesion to hydrophobic polymers. The hydrophobicity of vascular prostheses manufactured from Teflon or Dacron may be the reason why endothelialization of these grafts does not occur after implantation in humans. We modified films of polytetrafluoroethylene (Teflon) by nitrogen plasma and oxygen plasma treatments to ma...

Journal: :nephro-urology monthly 0
jalaladin khoshnevis department of vascular surgery, faculty of medicine, shahid beheshti university of medical sciences, ir iran mohammad reza reza sobhiyeh department of surgery, faculty of medicine, shahid beheshti university of medical sciences, ir iran +98-2122721144, [email protected] ; department of surgery, faculty of medicine, shahid beheshti university of medical sciences, ir iran +98-2122721144, [email protected] saran lotfolahzadah department of surgery, faculty of medicine, shahid beheshti university of medical sciences, ir iran +98-2122721144, [email protected] fatemah hoseinzadegan hoseinzadegan shirazi department of surgery, faculty of medicine, shahid beheshti university of medical sciences, ir iran +98-2122721144, [email protected] amir hosein jalali department of surgery, faculty of medicine, shahid beheshti university of medical sciences, ir iran +98-2122721144, [email protected]

background dialysis vascular access complications are considered as significant causes of morbidity in chronic hemodialysis patients. objectives the aim of the present study was a comparison of axillary loop and straight grafts patency and its complications in hemodialysis access. patients and methods in this cohort study conducted at shahid beheshti medical university, 77 patients who underwen...

Journal: :acta medica iranica 0
a. rabbani m. moini a. shojaeefard

arteriovenous fistula is considered as a prerequisite in patients with chronic renal failure undergoing hemodialysis. the purpose of this study was to compare the effectiveness and side effects if any of native vein and synthetic grafts in these patients. from april 2002 till july 2003, a total of 37 patients were referred to us for the utilization of these grafts. in 16 out of these patients w...

Journal: :Archives of facial plastic surgery 2006
D J Verret J L Leach J Gilmore

OBJECTIVE To evaluate the clinical outcomes with the use of a dual-porosity expanded polytetrafluoroethylene implant for midfacial rejuvenation. DESIGN An institutional review board-approved retrospective chart review was conducted of all patients who underwent implantation with the dual-porosity expanded polytetrafluoroethylene implant between 2001 and 2005. RESULTS A total of 170 patients...

2017
Jean-Luc Garden Jacques Richard Hervé Guillou Olivier Bourgeois

Polytetrafluoroethylene can be considered as a model for calorimetric studies of complex systems with thermodynamics transitions at ambient temperature. This polymer exhibits two phase transitions of different nature at 292 K and 303 K. We show that sensitive accalorimetry measurements allow us to study the thermodynamic behaviour of polytetrafluoroethylene when it is brought out of thermodynam...

Journal: :Bosnian journal of basic medical sciences 2008
Emir Solaković Dragan Totić Sid Solaković

There is still debate whether sintethic graft (polytetrafluoroethylene or Dacron) is equivalent to vein as bypass graft material for the above-knee femoropopliteal bypass. Therefore, we performed prospective randomized trial to compare vein with polytetrafluoroethylene/dacron for femoropopliteal bypasses with the distal anastomosis above the knee. Between January 2000 and June 2003, 121 femorop...

2009
Gowreeson Thevendran Rozanne Lord Khaled M Sarraf

Perigraft seroma is a rare complication of polytetrafluoroethylene grafts especially in the lower limb. It is often difficult to treat and recurrence is common. We present a case of a young woman who sustained a persistent perigraft seroma following a polytetrafluoroethylene graft in the proximal thigh, which was implanted as an alternative to an arteriovenous fistula. The cause was not ascerta...

Journal: :Turkish neurosurgery 2011
Aadil S Chagla Ritesh Kansal Balasubramaniam Srikant

Syringomyelia is condition in which a cyst or cavity forms inside the spinal cavity. Its management always remains a difficult. A variety of surgical techniques have been used in management of syringomyelia. Syringosubarachnoid shunt remains an effective method in management of syringomyelia. Shunt tube obstruction remains an important complication of shunt procedure. We describe a novel techni...

Journal: :Journal of the Japan Society of Colour Material 1975

2015
Rikuta Hamaya Yuko Ono Yasuyuki Chida Ryota Inokuchi Ken Kikuchi Tadanobu Tameda Choichiro Tase Kazuaki Shinohara

INTRODUCTION Polytetrafluoroethylene is ubiquitous in materials commonly used in cooking and industrial applications. Overheated polytetrafluoroethylene can generate toxic fumes, inducing acute pulmonary edema in some cases. However, neither the etiology nor the radiological features of this condition have been determined. For clarification, we report an illustrative case, together with the fir...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید