Journal: :international journal of smart electrical engineering 0
keyvan allahmoradi department of electrical engineering, birjand university of birjand, mohsen farshad department of electrical engineering, birjand university of birjand, omid bahrampour , department of electrical engineering, birjand university of birjand

this with the integration of distributed generation (dg) to meshed distribution systems, the operating time of the protective system becomes a major concern in order to avoid nuisance dg tripping. this paper proposes a new tripping characteristic for directional overcurrent relays (docrs) that can achieve a higher possible reduction of overall relays operating time in meshed distribution networ...

H. Shateri, S. Jamali,

This paper presents the effects of instrument transformers connection points on the measured impedance by distance relays in the presence of Flexible Alternating Current Transmission System (FACTS) devices with series connected branch. Distance relay tripping characteristic itself depends on the power system structural conditions, pre-fault operational conditions, and especially the ground ...

رجبی مشهدی, حبیب , ساده , جواد , صابری نوقابی, عباس ,

In a realistic and large power system, the overcurrent relay coordination problem considering different network topologies and different location of faults is stated as an optimization problem with a large number of constraints. In this paper, a new index is proposed to detect and remove the inactive inequality constraints in relay coordination problem. This index is defined for each relay pair...

Keyvan Allahmoradi Mohsen Farshad, Omid Bahrampour,

This with the integration of distributed generation (DG) to meshed distribution systems, the operating time of the protective system becomes a major concern in order to avoid nuisance DG tripping. This paper proposes a new tripping characteristic for directional overcurrent relays (DOCRs) that can achieve a higher possible reduction of overall relays operating time in meshed distribution networ...

Journal: :J. Applied Mathematics 2012
Feng-Zih Wu Chih-Ju Chou Ying Lu Jarm-Long Chung

This paper presents a practical and effective novel approach to curve fit electromechanical EM overcurrent OC relay characteristics. Based on singular value decomposition SVD , the curves are fitted with equation in state space under modal coordinates. The relationships between transfer function and Markov parameters are adopted in this research to represent the characteristic curves of EM OC r...

2012
Shumon Alam A. Annamalai

Relay based cooperative spectrum sensing elevates the spectrum sensing problems in harsh propagation conditions if the relay nodes are positioned suitably for the dynamic spectrum access systems. This article investigates the performance of relay based spectrum sensing (energy detection based) in myriad fading environments using the area under the receiver operating characteristic curve (AUC) p...

Journal: :IEICE Transactions 2009
Vo Nguyen Quoc Bao Hyung Yun Kong

In this paper, we study the performance of dual hop relaying in which the best relay selected by partial relay selection will help the source-destination link to overcome the channel impairment. Specifically, closed-form expressions for outage probability, symbol error probability and achievable diversity gain are derived using the statistical characteristic of the signal-to-noise ratio. Numeri...

2012
S. G. Srivani Chandrasekhar Reddy Atla K. P. Vittal

This paper presents the development of adaptive distance relay for protection of parallel transmission line with mutual coupling. The proposed adaptive relay, automatically adjusts its operation based on the acquisition of the data from distance relay of adjacent line and status of adjacent line from line circuit breaker IED (Intelligent Electronic Device). The zero sequence current of the adja...

2012
Muhd Hafizi Idris Surya Hardi Mohd Zamri Hasan

This paper describes the modeling of distance relay using Matlab/Simulink package. SimPowerSystem toolbox was used for detailed modeling of distance relay, transmission line and fault simulation. Inside the modeling, single line to ground (SLG) fault was choose to be the fault type and Mho type distance characteristic was choose to be as the protection scheme. A graphical user interface (GUI) w...

A. Sahebalam Gh. Abed Hodtani M. Osmani-Bojd,

In this paper, Ultra-wideband (UWB) multiple access relay channel with correlated noises at the relay and receiver is investigated. We obtain outer and inner bounds for the IEEE 802.15.3a UWB multiple access relay channel, and also, a diversity gain bound. Finally, we evaluate some results numerically and show that noise correlation coefficients play important role in determining relay position.