نتایج جستجو برای: scheimpflug camera

تعداد نتایج: 57591  

2016
Jay W. McLaren Katrin Wacker Katrina M. Kane Sanjay V. Patel

PURPOSE We compared corneal backscatter estimated from a Scheimpflug camera with backscatter estimated from a clinical confocal microscope across a wide range of corneal haze. METHODS A total of 59 corneas from 35 patients with a range of severity of Fuchs' endothelial corneal dystrophy and 15 corneas from 9 normal participants were examined using a Scheimpflug camera (Pentacam) and a confoca...

Journal: :بینا 0
علیرضا برادران رفیعی ar baradaran-rafii ocular tissue engineering research center, shahid beheshti university of medical sciences, tehran, iran تهران- پاسداران- بوستان نهم- خیابان پایدارفرد (خیابان امیر ابراهیمی)- پلاک 23- مرکز تحقیقات مهندسی بافت چشم محمد آقازاده امیری m aghazadeh amiri shahid beheshti university of medical sciencesدانشکده توانبخشی- دانشگاه علوم پزشکی شهید بهشتی سحر محقق s mohaghegh shahid beheshti university of medical sciencesدانشکده توانبخشی- دانشگاه علوم پزشکی شهید بهشتی بهاره خیری b kheiri shahid beheshti university of medical sciencesدانشگاه علوم پزشکی شهید بهشتی محمدمهدی صدوقی mm sadooghi shahid beheshti university of medical sciencesدانشگاه علوم پزشکی شهید بهشتی

purpose: to evaluate densitometry of crystalline lens after cxl procedure in keratoconic patients. methods: in a quasi-experimental study three-dimensional lens densitometry was performed by pentacam scheimpflug camera at base line and 6 months later. subject group contained patients with diagnosed progressive keratoconus who underwent cxl surgery (n = 40). control group contained aged-matched ...

Journal: :Journal of the Visualization Society of Japan 2004

2009
Rajeev Jain SPS Grewal

Rotating Scheimpflug imaging technology is used by instruments such as the Pentacam (Oculus) to measure the anterior and posterior corneal surfaces, as well as other anterior segment structures. Initially, Scheimpflug photography was used to obtain images of lens opacities for objective evaluation, but Pentacam-Scheimpflug camera is much wider in its clinical applications as a diagnostic tool f...

Journal: :Ophthalmology 2006
Shiro Amano Norihiko Honda Yuki Amano Satoru Yamagami Takashi Miyai Tomokazu Samejima Miyuki Ogata Kazunori Miyata

PURPOSE To compare central corneal thickness measurements and their reproducibility when taken by a rotating Scheimpflug camera, ultrasonic pachymetry, and scanning-slit corneal topography/pachymetry. DESIGN Experimental study. PARTICIPANTS Seventy-four eyes of 64 subjects without ocular abnormalities other than cataract. METHODS Corneal thickness measurements were compared among the 3 me...

Journal: :PeerJ PrePrints 2016
Indranil Sinharoy Prasanna Rangarajan Marc P. Christensen

We present a geometric model of image formation in Scheimpflug cameras that is most general. Scheimpflug imaging is commonly used is scientific and medical imaging either to increase the depth of field of the imager or to focus on tilted object surfaces. Existing Scheimpflug imaging models do not take into account the effect of pupil magnification (i.e. the ratio of the exit pupil diameter to t...

Journal: :Journal of the Visualization Society of Japan 2003

Journal: :Journal of refractive surgery 2009
Patricia Rosales Susana Marcos

PURPOSE To implement geometrical and optical distortion correction methods for anterior segment Scheimpflug images obtained with a commercially available system (Pentacam, Oculus Optikgeräte GmbH). METHODS Ray tracing algorithms were implemented to obtain corrected ocular surface geometry from the original images captured by the Pentacam's CCD camera. As details of the optical layout were not...

Journal: :Journal of the Japan society of photogrammetry and remote sensing 2017

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید