نتایج جستجو برای: schiotz

تعداد نتایج: 72  

Journal: :Investigative ophthalmology & visual science 1986
J G Feghali D T Azar P L Kaufman

Tonography was performed on 36 eyes of 15 normal and 3 primary open angle glaucoma patients using pneumatonography and classical Schiotz tonography. The average values of the coefficient of outflow facility (C) for the whole sample were virtually identical with both methods. However, both intersubject and interobserver variability were significantly higher with penumatonography. Although both m...

2017
Oded Ohana David Varssano Gabi Shemesh

PURPOSE Post-Descemet stripping endothelial keratoplasty (DSEK) patients are prone for intraocular pressure (IOP) elevations and glaucoma. Corneal characteristics influence various IOP measuring devices in various ways. The aim of this study was to evaluate the agreement between four different IOP measuring devices: Goldmann applanation tonometer (GAT), I-care pro, Tonopen XL, and Schiotz tonom...

Journal: :The British journal of ophthalmology 1965
C R Jackson

THERE is no doubt that applanation tonometry gives more accurate information about the level of intra-ocular pressure than does indentation tonometry. This increased accuracy is due to the fact that applanation readings approach very closely to the levels of pressure in the undisturbed eye (Po), owing to the small volume of fluid displaced by the application of the tonometer (Goldmann, 1957). A...

Journal: :British Journal of Ophthalmology 1928

Journal: :British Journal of Ophthalmology 1917

2014
Ismael Cordero

A Schiotz tonometer is an instrument for measuring the intraocular pressure (IOP). Although the Schiotz tonometer does not make as precise measurements as other types of tonometers, it is inexpensive, simple to use, durable, requires little maintenance, does not have electronics, does not require batteries, and can be stored for years between uses. These qualities make it well suited for screen...

Journal: :British Journal of Ophthalmology 1965

2010
Vassilios P Kozobolis Eleftherios I Paschalis Nikitas C Foudoulakis Stavrenia C Koukoula Georgios Labiris

PURPOSE To develop, characterize, and validate a prototype digital aqueous humor outflow tonographer (DAHOM). MATERIAL AND METHODS The DAHOM was developed, characterized, and validated in three phases. Phase 1 involved construction of the sensor. This was broadly based on the fundamental design of a typical Schiotz tonographer with a series of improvements, including corneal indentation, whic...

ژورنال: :مجله دانشکده پزشکی اصفهان 0
مهرداد مسعودی فر استادیار،گروه بیهوشی، دانشکده ی پزشکی، دانشگاه علوم پزشکی اصفهان، اصفهان، ایران ریحانک طلاکوب دانشیار، گروه بیهوشی، دانشکده ی پزشکی، دانشگاه علوم پزشکی اصفهان، اصفهان، ایران پیام ابراهیمی فر دانشجوی پزشکی، دانشکده ی پزشکی و کمیته ی تحقیقات دانشجویی، دانشگاه علوم پزشکی اصفهان، اصفهان، ایران

مقدمه: یکی از مشکلات جراحان مغز و اعصاب در اعمال کرانیوتومی بالا بودن فشار داخل جمجمه (intracranial pressure یا icp) هنگام برش دورا و خطر بیرون زدگی نسج مغز و آسیب عصبی است. هدف از اجرای این طرح، تعیین ارتباط بین icp اندازه گرفته شده به وسیله ی تونومتر schiotz قبل از باز کردن دورا و icp بر اساس یافته های سی تی اسکن در بیماران کاندید عمل کرانیوتومی بود. روش ها: در یک مطالعه ی مقطعی در بیمارستان ...

Journal: :Investigative ophthalmology 1964
R A MOSES

In enucleated stored eyes facility of outflow is diminished by large corneal distortions. The radius of distortion at which decrease in facility is noted is related to the shape of the distortion. Of the three distorting devices tested, a plane surface decreased the facility at the smallest radius of distortion, a convex surface was intermediate in effect, while the Schiotz tonometer allowed th...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید