نتایج جستجو برای: selective

تعداد نتایج: 199269  

Journal: :journal of physical & theoretical chemistry 2004
hossein aghaei masood giahi majjid arvand mehran aghaei

tin(ii)-ion-selective electrode consisting of dibenzo-18-crown-6 (db18c6) as an ionophore inpvc matrix was developed. the influences of membrane composition, selectivity, response time,reversibility and temperature on the electrode performance were investigated. the electrodeshowed a near nernstian response for sn2+ ions over a concentration range from 1.0× 10-6 – 1.0× 10-2 m with a slope of 27...

Journal: :journal of physical & theoretical chemistry 2007
m. aghaie m. h. fekri m. giahi e. baghdar s. farhadi

in order to study the cu(ii) ion selective electrode, an optimized membrane was prepared by mixing of 30 mg of pvc powdered, 5 mg of considered ionophore, 60 mg of plasticizer and 5 mg of additive. the sensor showed a near nernstian response for cu(ii) ions over a concentration range from 1.0×0-6 –1.0×0-2 m with a slope of 28.90.5 mv per concentration decade with a working ph range of 3.5-6.3. ...

Journal: :journal of physical & theoretical chemistry 2011
m. kia a. islamnezhad sh. shariati

in order to preparing strontium ion selective electrode 6-(4- nitropheny1)-2-pheny14, 4- dipropy1-3, 5-diaza-bicyclo [3, 1, 0] hex-2-ene (npdbh) was used as an ionophore. this electrode responds to sr (ii)ion with a sensitivity of 28.2 ± 0.5 mv/decade over the range 1.0 x 10-6 to 1.0 mat ph 3.0-10.0. thelimit of detection was 2.4 x 10-7 m. the influences of membrane composition, the ph of the t...

پایان نامه :دانشگاه آزاد اسلامی - دانشگاه آزاد اسلامی واحد یزد - دانشکده شیمی 1392

in this study, a simple, rapid and selective method was developed for the determination of dexamethasone. the proposed method is based on inhibitory effect of dexamethasone on the oxidation of orange-g by bromate in sulfuric acid media. the reaction was followed spectrophotometrically at 478.5 nm (?max). under optimum experimental conditions, (72.6 ?mol l-1 of orange-g, 0.76 mol l-1 of h2so4, 0...

ژورنال: :مجله علمی - پژوهشی دانشگاه علوم پزشکی سبزوار 1970
حبیب اله اسماعیلی عطیه منصوری فتانه نظری معصومه کردی

background and purpose: left to their own choice, parturients will usually select positions they find most comfortable and will frequently change their positions over the course of labor. maternal changing the positions will adjust fetus alignment to pass through the birth canal. therefore, maternal positioning choice will include those positions with maximum comfort and those which improve the...

Journal: :Bulletin of the Psychonomic Society 1979

Journal: :ژورنال پزشکی بین المللی الکترونیک 0
mitra rooin peikar sepehr rasekhi hosein hamadiyan

patients with type 1 diabetes mellitus have a high prevalence of coeliac disease, symptoms of which are often mild, atypical, or absent. untreated coeliac disease is associated with an increased risk of malignancy, particularly of lymphoma. therefore, we report a 9-year-old girl with coeliac disease, diabetes type 1 and selective iga deficiency. a 9-year-old female patient presented in august 2...

Journal: :journal of physical & theoretical chemistry 2012
m. h. fekri m. darvishpour

a pvc membrane ni(ii) ion selective electrode has been constructed using (1e,2e)-bis(2-aminophenyl)n'1,n'2-dihydroxyethanebis as membrane carrier. the electrode exhibited a goodpotentiometric response for ni(ii) over a wide concentration range 1.0×10-4 to 1.0×10-1m with aslope of 29.4±0.5 mv/decade a and a working ph range of 6.5-9.0. it had a fast response time of≤20s. the best performance was...

Journal: :journal of physical & theoretical chemistry 2012
r. aminameli m. h. fekri h. shafie m. darvishpour h. khanmohammadi

a pvc membrane fe(iii) ion selective electrode has been constructed using a new macrocyclic asmembrane carrier.the electrode exhibits a good potentiometric response for fe(iii) over a wideconcentration range 1.0×10-4 to 1.0×10-1m with a slope 19.4±0.5 mv/decade a and a working phrange of 6.5-9.0. it has a fast response time ≤30s.the best performance was observed with themembrance having the 30....

Journal: :journal of physical & theoretical chemistry 2004
h. aghaie m. giahi1 giahi m. aghaei m. arvand3

we found that dibenzo-18-crown-6 (db18c6) can be used as an ionophore to make a tin (ii)-ionselectivemembrane electrode. the electrode exhibits a near nernstian response for sn2+ ions over aconcentration range from 1.0× 10-6 – 1.0× 10-2 m with a slope of 27.5 ± 0.6 mv per concentration decadein an acidic solution (ph=1). the limit of detection was 8.0× 10-7 m. it has a response time of < 20s an...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید