نتایج جستجو برای: tono

تعداد نتایج: 362  

2016
Chizoba Onochie Obiekwe Okoye Adunola Ogunro Tade Aribaba Kunle Hassan Adeola Onakoya

OBJECTIVE The aim of this study was to compare intraocular pressure (IOP) measured with the Tono-Pen® to that measured using the Goldmann applanation tonometer (GAT) in patients with primary open angle glaucoma attending a glaucoma clinic. SUBJECTS AND METHODS A comparative clinic-based observational study was conducted involving 75 patients (39 men and 36 women) attending a glaucoma clinic i...

2016
Di Ma Chong-Bo Chen Jiajian Liang Zhihao Lu Haoyu Chen Mingzhi Zhang

Tono-Pen and TonoVet have been used in rabbits to measure intraocular pressure (IOP) and investigate the effect of IOP lowering therapies. Therefore, their reliability and accuracy are very important and deserve careful evaluation. Our results showed that the with-subject deviation (Sw) and intraclass correlation coefficient (ICC) of the TonoVet and Tono-Pen were 0.61 mmHg/0.83 mmHg and 0.97/0....

Journal: :The British journal of ophthalmology 1998
A Azuara-Blanco T K Bhojani A R Sarhan C T Pillai H S Dua

AIMS To evaluate the intraocular pressure (IOP) measurements in patients with band keratopathy or glued corneas obtained from affected and non-affected areas. METHODS 15 patients with band keratopathy or glued corneas were prospectively recruited. When both eyes were affected, only the right eye was analysed. Tono-Pen readings of IOP were obtained sequentially from the affected and non-affect...

Journal: :The British journal of ophthalmology 1994
A Midelfart A Wigers

A clinical evaluation of a new electron ProTon tonometer was performed comparing the values of intraocular pressure (IOP) measured using this instrument with those determined by a similar instrument, Tono-Pen XL, and by Goldmann applanation tonometry. The mean IOP measured in 106 eyes with the ProTon tonometer was not significantly different from that determined with Goldmann applanation, while...

2017
In Kyun Hahn Jae Yong Kim Myoung Joon Kim Hungwon Tchah Chan Hee Moon

PURPOSE To assess the validity of central corneal thickness (CCT) and corrected intraocular pressure (IOP) values obtained by tono-pachymetry in non-surgical and post-photorefractive keratectomy (PRK) eyes. METHODS For the study, 108 young healthy participants and 108 patients who had PRK were enrolled. Measurements were randomly performed by tono-pachymetry, ultrasonic (US) pachymetry, and G...

Journal: :BMC Ophthalmology 2008
Spyridon K Charisis Harilaos S Ginis Georgios A Kounis Miltiadis K Tsilimbaris

BACKGROUND The purpose of this study is to evaluate the use of Tono-Pen XL in measuring IOP during the application of a suction ring in rabbit eyes with manometrically controlled IOP. METHODS Tono-Pen XL was calibrated against direct manometry in 10 rabbit eyes. A suction ring was then applied in 4 rabbit eyes and the IOP was determined manometrically during suction ring application at 350 mm...

2010
Sheng-Yao Hsu Shu-Fang Lin Ai-Hsi Hsu

Objective: The purpose of this preliminary study was to compare differences in the measurement of intraocular pressure (IOP) between TonoPen tonometry and Goldmann applanation tonometry (GAT) in healthy individuals and those with coexisting illnesses. Patients and Methods: This prospective study included 42 individuals who were further categorized into two groups. Group 1 consisted of 20 health...

Journal: :Investigative ophthalmology & visual science 2011
Junhua Tang Xueliang Pan Paul A Weber Jun Liu

PURPOSE To experimentally examine the effect of corneal modulus on Goldmann applanation tonometry (GAT) and Tono-pen (Tono-pen XL, Reichert, Inc., Depew, NY) measurements of intraocular pressure (IOP) in a canine eye model. METHODS Twenty-one canine globes were recovered from healthy animals. IOP was controlled at 10, 15, 20, 30, and 40 mm Hg and measured by GAT and Tono-pen following standar...

Journal: :The British journal of ophthalmology 1992
O Geyer Y Mayron A Loewenstein M Neudorfer L Rothkoff M Lazar

Oculab Tono-Pen tonometry was compared with Goldmann applanation tonometry in 82 eyes of 82 patients with normal corneas and in 54 eyes of 54 patients who had undergone penetrating keratoplasty and whose corneas did not preclude the use of Goldmann tonometer. We found that the intraocular pressure (IOP) in 48% of the eyes with normal corneas and in 57% after keratoplasty has different measureme...

Journal: :The British journal of ophthalmology 2004
A C Browning A Bhan A P Rotchford S Shah H S Dua

BACKGROUND/AIM To compare intraocular pressure (IOP) measurements taken by the Goldmann applanation tonometer, the Tono-Pen and the ocular blood flow pneumotonometer in eyes with varying central corneal thickness (CCT) due to penetrating keratoplasty (PK), keratoconus (KC), and Fuchs' endothelial dystrophy (FED). METHODS IOP was measured with the Goldmann applanation tonometer, Tono-Pen XL, a...