Volumetric evaluation of pituitary gland in dog and cat using computed tomography

نویسندگان

  • Mohammad Molazem Department of Radiology and Surgery, Faculty of Veterinary Medicine, University of Tehran, Tehran, Iran
  • Salah Nadimi DVM graduate, Faculty of Veterinary Medicine, University of Tabriz, Tabriz, Iran
  • Seyedhosein Jarolmasjed Department of Clinical Sciences, Faculty of Veterinary Medicine, University of Tabriz, Tabriz, Iran
چکیده مقاله:

The objective of this study was to evaluate the pituitary gland dimensions due to age and weight using computed tomography (CT) in dogs and cats. The CT images of pituitary gland were assessed in 11 client-owned dogs (six males and five females; age range, 1 to 9 years) and 15 client-owned cats (eight males and seven females; age range, 1 to 14 years) with no evidence of pituitary diseases. The length, height, width and volume of the pituitary gland were measured in sagittal and transverse planes. Mean pituitary length, width, height and volume (± standard deviation: SD) were respectively 4.96 (± 0.69 mm), 3.62 (± 0.64 mm), 2.62 (± 0.05 mm) and 26.19 (± 7.99 mm3) in cats and were 7.00 (± 2.14 mm), 4.80 (± 1.20 mm), 3.80 (± 0.70 mm) and 77.53 (± 51.64 mm3) in dogs, respectively. Mean pituitary height-to-brain ratio (P:B ratio), (± SD) in cats and dogs was 0.28 (± 0.05) and 0.21 (± 0.03), respectively and mean percent of pituitary volume to brain volume (± SD) in cats and dogs was 0.10 (± 0.05) and 0.10 (± 0.07), respectively. There was no significant correlation between the size of pituitary gland and age, weight and body condition score (BCS) in dogs, however in cats, significant difference was found between height of pituitary gland and weight and BCS, pituitary width and weight and P:B ratio and BCS. These findings could be useful to identify abnormal pituitary gland enlargement in CT images. To be more accurate in the assessments, further studies are required.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-dimensional Volumetric Ultrasonography of Enlarged Adrenal Gland in Dog

Objective: Detection and evaluation of adrenal glands are complex problems in conventional ultrasonography in dogs. Using three-dimensional (3D) ultrasonography (US) in adrenal gland volume evaluation can add new potential for further adrenal studies. Design: Descriptive study Animals: a total of 10 mix breed dogs Procedures: The dogs underwent two dimensional (2D) and 3D US of the adrenal g...

متن کامل

hazard evaluation of gas condensate stabilization and dehydration unit of parsian gas refinery using hazop procedures

شناسایی مخاطرات در واحد 400 پالایشگاه گاز پارسیان. در این پروزه با بکارگیری از تکنیک hazop به شناسا یی مخاطرات ، انحرافات ممکن و در صورت لزوم ارایه راهکارهای مناسب جهت افزایش ایمنی فرا یند پرداخته میگردد. شرایط عملیاتی مخاطره آمیز نظیر فشار و دمای بالا و وجود ترکیبات مختلف سمی و قابل انفجار در واحدهای پالایش گاز، ضرورت توجه به موارد ایمنی در این چنین واحدهایی را مشخص می سازد. مطالعه hazop یک ر...

Evaluation of left ventricular function using volumetric computed tomography in the clinical setting.

OBJECTIVE To correlate the left ventricular parameters obtained with 64-slice Volumetric Computed Tomography (VCT) with those obtained with the reference standard, cardiovascular magnetic resonance (CMR) imaging. METHODS VCT and a 3.0T MRI scanner were used. Results from both studies were independently evaluated by two cardiologists. A linear correlation and a paired Student's t test were use...

متن کامل

Evaluation of Metal Artifact Reduction software in Computed Tomography

Introduction: The image quality of computed tomography (CT) can be seriously lowered by metal implants of patients. These implants are known to exert a significant impact on diagnostic accuracy due to artifacts. The current study aimed to assess the usefulness of Metal Artifact Reduction (MAR) software in the reduction of metal artifacts, in comparison to iterative rec...

متن کامل

Volumetric accuracy of cone-beam computed tomography

PURPOSE This study was performed to investigate the influence of object shape and distance from the center of the image on the volumetric accuracy of cone-beam computed tomography (CBCT) scans, according to different parameters of tube voltage and current. MATERIALS AND METHODS Four geometric objects (cylinder, cube, pyramid, and hexagon) with predefined dimensions were fabricated. The object...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 9  شماره 4

صفحات  337- 341

تاریخ انتشار 2018-12-15

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023