نتایج جستجو برای: power system harmonics

تعداد نتایج: 2587527  

In this paper, we propose a Controlled Inductance Power Filter (CIPF) to solve power quality problems in industrial DC power supply systems. This method is based on the theory of magnetic potential equilibrium combined with active hybrid filter technology. Initially the system structure and filter wiring scheme are presented and the equivalent circuit is performed with the mathematical models o...

Journal: :مهندسی برق و الکترونیک ایران 0
s. h. hosseini k. mohammadi

nowadays with increasing use of numerous nonlinear loads, voltage and current harmonics in power systems are one of the most important problems power engineers encounter. many of these nonlinear loads, because of their dynamic natures, inject time-varying harmonics into power system. common techniques applied for harmonics measurement and assessment such as fft have significant errors in presen...

Thyristor controlled static compensators consist of two basic schemes, TCR and TSC. Owing to the discontinuous current in TCR, current harmonics are generated in the supply system. This paper introduces two methods for the reduction of these harmonics. On the basis of the coordination or uncoordination of turn ratios with harmonic reduction levels, each method is described in two alternative sc...

ژورنال: Journal of Railway Research 2018
Fazel, Seyed Saeed, Foiadelli, Federica, Jafari Kaleybar, Hamed, Madadi Kojabadi, Hossein, Brenna, Morris ,

Abstract Traditional railway power supply systems impose substantial power quality problems (PQ) on the utility network, such as unbalance, harmonics and a large amount of reactive power. This paper proposes a topology based on three-phase to single-phase modular multilevel converters (MMC) to obviate these problems. The MMC based traction substations (TSS) are connected directly to the utili...

Journal: :international journal of smart electrical engineering 2014
haidar samet mohammad amin jarrahi

electric arc furnace (eaf) is one of the largest loads in electric power systems. it is highly time varying and nonlinear. its reactive power variations cause voltage fluctuations in nearby system which is known as flicker. on the other hand the nonlinear voltage-current characteristic causes strong voltage and current harmonics in eaf. to this end flexible ac transmission systems (facts) techn...

Journal: :تحقیقات نوین در برق 0
عبدالرضا ربیعی abdorreza rabiee بهرام اصغریان دستنائی bahram asgharyan

abstract: one the most important problems in recent sensitive loads is the quality of voltage. for this challenge custom power devices are used in distribution systems. dynamic voltage restorer (dvr) is a custom power device that improves voltage, decrease power distortion, filter harmonics and balance distributed generations (dgs) with low voltage distribution system. in this paper, a new algo...

Journal: :journal of artificial intelligence in electrical engineering 0
parisaalipour alipour department of engineering, ahar branch, islamic azad university, ahar, iran mahdisalimi salimi department of engineering, ardabil branch, islamic azad university, ardabil, iran

in this paper, a novel control method for photovoltaic converter connection to the national gridis presented, so in addition to the injection control by solar arrays to the grid, this method cancompensate reactive power and harmonics in the load current. the system will be connected inparallel between the grid and load. the proposed system supplies all load power consumption(including active po...

K. Mohammadi, S. H. Hosseini,

Nowadays with increasing use of numerous nonlinear loads, voltage and current harmonics in power systems are one of the most important problems power engineers encounter. Many of these nonlinear loads, because of their dynamic natures, inject time-varying harmonics into power system. Common techniques applied for harmonics measurement and assessment such as FFT have significant errors in presen...

Recently, increasing of non-linear loads in the power distribution network has been increased harmonics in these networks. The harmonics problems get worse and complicated by installation of power factor correction capacitors and filters. But the Distributed Generations (DGs) interface inverters with properly control can help to improve power quality, harmonic compensation and voltage unbalance...

Journal: :EURASIP J. Adv. Sig. Proc. 2007
Li Qi Lewei Qian Stephen Woodruff David A. Cartes

Proliferation of nonlinear loads in power systems has increased harmonic pollution and deteriorated power quality. Not required to have prior knowledge of existing harmonics, Prony analysis detects frequencies, magnitudes, phases, and especially damping factors of exponential decaying or growing transient harmonics. In this paper, Prony analysis is implemented to supervise power system transien...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید