Electromagnetic forces in power transformer windings are produced by interaction between the leakage fluxes and current passing them. Since the leakage flux distribution along the windings height is in two axial and radial directions, so the electromagnetic forces have two components, radial and axial. There is a risk that a large electromagnetic force due to the short circuit or inrush currents, can cause the windings to be deform, rupture, and/or displace, if the transformer and winding holders structure is not designed or assembled properly. Also, these mechanical changes can damage insulation between two or more adjacent turns of a winding and so, produce the local inter-turn fault. Occurrence of any fault in windings will change the electromagnetic force distribution in transformers and will cause developing secondary faults. Hence, this contribution is aimed at characterizing the electromagnetic forces behavior in power transformers and determines the changes of force values after occurring winding mechanical and inter-turn. The study keeps at disposal a two-winding, three phase, 8 MVA power transformer, on their windings faults are imposed and investigated through the FEM analysis. The accuracy of the created FEM model is firstly validated using analytical methods for transformer healthy condition, and then the winding shorted turn fault along with the mechanical faults are considered using 3D FEM model. The extracted characteristic signatures attained to different type of winding faults is expected to be useful at the design stage of power transformers.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Recognition and Location of Power Transformer Turn to Turn Fault by Analysis of Winding Imposed Forces

Turn to turn fault is one of the major internal failures in the power transformers that if it is not quickly detected, can be extended and led to a complete transformer breakdown. So, the diagnosis and location of the turn to turn fault of the power transformer, as one of the most important equipment in the power system, is the main objective of this paper. For this purpose, a detailed model of...

متن کامل

Improvement of Electromagnetic Forces in a Single-Phase Induction Motor by Providing a New Winding Distribution

Single-phase induction motors have a wide range of domestic and industrial applications. These motors have a squirrel cage rotor and their stator usually has two windings: main and auxiliary. The use of auxiliary winding in the structure of single-phase induction motors creates two unbalance and asymmetric phases. This causes to increase the spatial harmonics of the field in the air gap, and al...

متن کامل

Transformer Models for Detection of Incipient Internal Winding Faults

A method of modeling internal turn-to-earth and turn-toturn faults in distribution transformer is discussed in this paper. The models are entirely compatible with the Alternative Transients Program(ATP). The simulation of the faults is based on known leakage factors between the various coils of the transformer. These leakage factors are evaluated by using a simple method implemented in this pap...

متن کامل

Power Transformer Incipient Faults Monitoring

Power transformers are important and expensive components in the electric power system. The knowledge of the actual status of the transformer insulation behavior, load tap changer performance, temperature, and load condition is necessary in order to evaluate the service performance concerning reliability, availability and safety. Systems abnormalities, loading, switching and ambient condition n...

متن کامل

Transformer Internal Winding Faults Diagnosis Methods: A Review

A transformer is a vital component in any power system network and its catastrophic failure may cause disturbance in the proper operation of electrical power system network. Therefore, it requires continuous monitoring and diagnostics of its operation. This paper presents the several on-line and off-line techniques related with internal winding fault detection in transformers. This paper also r...

متن کامل

Improved Modeling of Power Transformer Winding Using PSO

The paper discusses an improved modeling of transformer windings based on particle swarm optimization algorithm (PSO) and frequency response analysis (FRA). With the purpose to accurately identify transformer windings parameters a model-based identification approach is introduced using a well-known lumped parameter model. It includes search space estimation using analytical calculations, which ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 6  شماره 1

صفحات  40- 49

تاریخ انتشار 2018-06-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023