Nano Liposomes labeled with 99mTc-HMPAO, A Novel Agent for Blood Pool Imaging

نویسندگان

  • Kamran Aryana Nuclear Medicine Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
  • kayvan sadri Nuclear Medicine Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.
  • Mahmoud Reza Jaafari Biotechcology Research Center, Nanotechnology Research Center, School of Pharmacy, MUMS, Mashhad, Iran
  • Ramin Sadeghi Nuclear Medicine Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
  • Salimeh Momenypoor Biotechcology Research Center, Nanotechnology Research Center, School of Pharmacy, MUMS, Mashhad, Iran
  • Seyed Rasoul Zakavi Nuclear Medicine Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
چکیده مقاله:

In-vitro labeling of RBC with 99mTc is an intricate procedure and there is always a need foran alternate blood pool imaging agent. The aim of this study was to prepare an effective nanosized liposome (NLs) similar to human RBC for blood pool scintigraphy. This study formulatesPEG-NLs and non-PEG-NLs using film method plus high pressure homogenization technique.Biodistribution studies were performed on BALB/C mice 1, 4 and 24 h after tail vein injectionof labeled NLs with 99mTc hexamethylpropylene-amine-oxime (99mTc-HMPAO). Planar imageswere acquired using a 256 × 256 matrix following99m Tc-HMPAO-NLs injection into ear veinof rabbits 1, 2 and 24 h later. SPECT images were obtained 15 minutes after the injection (64slices, 30 second/projection). The mean diameter, zeta potential and polydispersity index (PDI)of the PEG-NLs and the NLs were (80.88 ± 0.594 nm, -12.5 ± 0.56 mv, 0.158 ± 0.025) and(94.14 ± 0.114 nm, -35.5 ± 0.67 mv and 0.198 ± 0.007), respectively. 99mTc-HMPAO-PEG-NLsshowed a significant circulation tracer activity (7.74 ± 1.63%ID/g at 1 h and 4.9 ± 0.77 %ID/gat 4 h), with low liver accumulation (12.07 ± 3.66 %ID/g at 1 h and 14.85 ± 1.3 %ID/g at 4 h).Heart to liver, spleen and background ROIs (region of interests) for 99m c-HMPAO-PEG-NLswere 1.25, 4 and 4.28 respectively at 2 h which changed to 1.06, 1.75 and 2.51 respectivelyat 24 h. The 99mTc-HMPAO-PEG-NLs with a prolonged blood circulation time could be anexcellent RBC alternative for scintigraphy and gastrointestinal bleeding.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

nano liposomes labeled with 99mtc-hmpao, a novel agent for blood pool imaging

in-vitro labeling of rbc with 99mtc is an intricate procedure and there is always a need foran alternate blood pool imaging agent. the aim of this study was to prepare an effective nanosized liposome (nls) similar to human rbc for blood pool scintigraphy. this study formulatespeg-nls and non-peg-nls using film method plus high pressure homogenization technique.biodistribution studies were perfo...

متن کامل

Nano Liposomes Labeled with (99m)Tc-HMPAO, a Novel Agent for Blood Pool Imaging.

In-vitro labeling of RBC with (99m)Tc is an intricate procedure and there is always a need for an alternate blood pool imaging agent. The aim of this study was to prepare an effective nano sized liposome (NLs) similar to human RBC for blood pool scintigraphy. This study formulates PEG-NLs and non-PEG-NLs using film method plus high pressure homogenization technique. Biodistribution studies were...

متن کامل

Imaging of Clot by 99mTc-HMPAO Labeled Platelet in Animal Model Induced Thrombosis

99mTc-HMPAO labeled platelet (LP) imaging may integrate thrombosis imaging into routine clinical procedures. In the current study, we assessed the feasibility of the use of 99mTc-HMPAO LP for imaging of small clots in an animal model. Thrombosis was induced by application of FeCl3 solution in the distal part of the inferior vena cava (IVC) of a 6100 g anesthetiz...

متن کامل

Imaging of Clot by 99mTc-HMPAO Labeled Platelet in Animal Model Induced Thrombosis

99mTc-HMPAO labeled platelet (LP) imaging may integrate thrombosis imaging into routine clinical procedures. In the current study, we assessed the feasibility of the use of 99mTc-HMPAO LP for imaging of small clots in an animal model. Thrombosis was induced by application of FeCl3 solution in the distal part of the inferior vena cava (IVC) of a 6100 g anesthetiz...

متن کامل

Preparation and radiochemical control of 99mTc labeled blood pool agent for in vivo labelling of the red blood cells.

Our aim was to prepare cheap blood pool imaging kits by simplified method to overcome the burden on purchase department of MINAR, Nishtar Hospital, Multan, Pakistan. Secondarily, prompt supply of kits should save the time of patient during transportation. A total of 24 subjects selected for this study were equally divided into two groups. Mixture of stannous chloride and sodium pyrophosphate so...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 14  شماره 4

صفحات  981- 988

تاریخ انتشار 2015-10-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023