Nile Blue- Chitosan Composite as a new Electrochemical Sensor for Uric Acid on Glassy Carbon Electrode

نویسندگان

چکیده مقاله:

Nile blue-Chitosan NB-CH as a new type of organic days-organic composite was made using Nile blue and chitosan. The NB-CH composite was made using a 0.005 M solution of Nile blue NB and a 7 solution of chitosan. To do this, a mixture of Nile blue and Chitosan with the ratio of 2:1 was prepared. The electrocatalytic oxidation of uric acid UA has been studied on glassy carbon electrode by NB-CH using electrochemical techniques. The NB-CH electrode showed one pair of peaks in 0.5 M KHSO4 as a supporting electrolyte. The catalytic currents are linearly related to UA concentrations in the ranges of 3×10-5 to 1.8×10-4 M and limit of detection 1.2 ×10-6 M with surface coverage of 2 ×10-8 mol cm-2.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Hydroxylamine Electrochemical Sensor Based on an Oxadiazol Derivative and Multi-wall Carbon Nanotuhes Modified Glassy Carbon Electrode

A new hydroxylamine sensor has been fabricated by immobilizing oxadiazol denvative at the surface ol aglassy carbon electrode (GCE) modified by multi-wall carbon nanotube (MIVCNT). The adsorbed thin Illms oroxadiazol derivative on the MWCNT modified GCE show a pair of peaks with surface confined characierisnus.The oxadiazol derivative MWCNI (OMWCNT) modified GCE shows highly catalytic activity ...

متن کامل

Electrochemical Sensor for Determination of Fenitrothion at Multi-wall Carbon Nanotubes Modified Glassy Carbon Electrode

A sensor, based on multi-wall carbon nanotubes modified glassy carbon electrode (MWCNT/GCE), was developed for determination of fenitrothion. Determining the surface area of MWCNT/GCE showed that this surface is three times more active than that of a glassy carbon electrode. The experimental parameters, such as the amount of MWCNTs, pH of the fenitrothion solution, preconcentration potential an...

متن کامل

The Enhanced Photo-Electrochemical Detection of Uric Acid on Au Nanoparticles Modified Glassy Carbon Electrode

In this work, a sensitive and novel method for determining uric acid (UA) has been developed, in which the glassy carbon electrode (GCE) was modified with electrodeposition Au nanoparticles and used to monitor the concentration of UA with the assistant of visible light illumination. The morphology of the Au nanoparticles deposited on GCE surface were characterized by scanning electron microscop...

متن کامل

Simultaneous Determination of Ascorbic Acid, Uric Acid and Acetaminophen on a Glassy Carbon Electrode Coated with a Novel Single Walled Carbon Nanotubes/ Chitosan/ MCM-41 Composite

The present work demonstrates that simultaneous determination of ascorbic acid (AA), uric acid (UA) and acetaminophen (ACT) can be performed on a novel single walled carbon nanotubes (SWCNTs), chitosan (CHIT) and MCM-41 composite modified glassy carbon electrode (SWCNTs-CHIT-MCM-41/GCE). The electro-oxidations of AA, UA and ACT were investigated by using differential pulse voltammetry (DPV), ch...

متن کامل

A New Electrochemical Sensor for Determination of Zolpidem by Carbon Paste Electrode Modified with SnS@SnO2NP

Zolpidem is a drug that is easily attached to the GABA receptors in the brain. This property makes it very effective for tranquilizing as well as hypnagogia. According to the advantages of electrochemical analysis like high selectivity, high sensitivity, low concentration of analyte, cost-effective, portable and easy-to-use setup, they gained high amount of attention among scientists for determ...

متن کامل

Electrochemical Sensor for Determination of Ascorbic Acid Using a 2-Chlorobenzoyl Ferrocene/Carbon Nanotube Paste Electrode

A chemically modified carbon paste electrode with 2-chlorobenzoyl ferrocene (2CBF) and carbon nanotube (2CBFCNPE) was employed to study the electrocatalytic oxidation of ascorbic acid in aqueous solution using cyclic voltammetry, square wave voltammetry and chronoamperometry. The diffusion coefficient (D = 1.42 × 10-6 cm2 s-1), and the kinetic parameter such as ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 8  شماره 1

صفحات  1- 9

تاریخ انتشار 2015-02-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023