نتایج جستجو برای: ultrasound surface probe

تعداد نتایج: 820675  

Journal: :IEEE Transactions on Robotics 2017

In this study, the effect of low-frequency ultrasound on the structure and activity of urease enzyme has been investigated. For this purpose, the enzyme was exposed to ultrasound with 20 kHz frequency at different time intervals. The urease enzyme was immobilized on the surface of magnetic nanoparticles (Fe2O3), and activated silica gel with 89% and 66% efficiency respectively. The enzyme activ...

Journal: :Anesthesia: Essays and Researches 2015

Manijeh Motevalian, Mohammad Bagher Shiran, Rezvan Ravanfar, Shahab Bohlooli,

It is over several decades that ultrasound is used to enhance the transdermal drug delivery (phonphoresis). The mechanism of the enhancement is not fully understood and the ability of ultrasound on the enhancement for some drugs is unclear. The effect of continuous wave 870 KHz ultrasound at intensity of 1 W/cm 2 for 15 minutes on transdermal absorption of piroxicam from solution and gel formu...

Journal: :Journal of endourology 2010
Mathew D Sorensen Anup R Shah Michael S Canney Oleg A Sapozhnikov Joel M H Teichman Michael R Bailey

PURPOSE A prototype ultrasound-based probe for use in ureteroscopy was used for in vitro measurements of stone fragments in a porcine kidney. METHODS Fifteen human stones consisting of three different compositions were placed deep in the collecting system of a porcine kidney. A 2 MHz, 1.2 mm (3.6F) needle hydrophone was used to send and receive ultrasound pulses for stone sizing. Calculated s...

2017
Eric M. Moult Andras Lasso Tamas Ungi Csaba Pinter Mattea Welch Gabor Fichtinger

In tracked ultrasound systems, temporal misalignment between image and tracker data results in incorrect image pose. We present a fully automatic temporal calibration. We image a flat plate in water with a tracked probe undergoing periodic uniaxial freehand translation. Using robust line detection scheme, we compute temporal misalignment as difference between probe and corresponding image posit...

2009
Ting Wu Zhaoying Zhou Qun Wang Xing Yang Mingfei Xiao

Although ultrasound cavitation must be avoided for safe diagnostic applications, the ability of ultrasound to disrupt cell membranes has taken on increasing significance as a method to facilitate drug and gene delivery. A new ultrasonic resonance driving method is introduced to penetrate rigid wall plant cells or oocytes with springy cell membranes. When a reasonable design is created, ultrasou...

Journal: :Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine 2014
Matthew W Lawrence James Blanks Ruben Ayala Douglas Talk Diana Macian Jessie Glasser Joel M Schofer

OBJECTIVES The purpose of this study was to determine the hospital-wide incidence of bacterial contamination of point-of-care (bedside) ultrasound probes and coupling gel at a single academic medical center to predict the risk of nosocomial spread of infection. METHODS Bacterial cultures were performed on all point-of-care ultrasound probe surfaces and associated gel bottles in our institutio...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید