نتایج جستجو برای: dynamic pull in voltage

تعداد نتایج: 17074557  

2006
S. Jayapal

Abstract. Dual threshold voltage and forward body bias techniques are effective ways to optimally balance the standby leakage power and performance. In this paper, we propose a novel fine-grained forward body biasing scheme for monotonic static logic circuits. In the proposed scheme, the forward body bias is applied to high threshold voltage of either the pull-up or the pull-down network based ...

Journal: :ACM Transactions on Architecture and Code Optimization 2004

Journal: :Optics express 2005
Guoyang Xu Zhifu Liu Jing Ma Boyang Liu Seng-Tiong Ho Lian Wang Peiwang Zhu Tobin Marks Jingdong Luo Alex Jen

A novel organic electro-optic (EO) modulator using transparent conducting oxides (ZnO and In2O3) as electrodes is demonstrated for the first time. The modulator employs the poled guest-host chromophore/polymer material AJL8/APC having r33=35pm/V and is able to achieve a low Vpi=2.8 V switching voltage for an 8mm-long device at a wavelength of 1.31ìm. This corresponds to a Vpi=1.1 V switching vo...

Journal: :the modares journal of electrical engineering 2011
mona ghassemi hossin mohseni kaveh niayesh amir abbas shayegani akmal

although in recent two decades, the concept of dielectric barrier discharges (dbds) have been developed in ozone production well, air pollution control, plasma screens and control of chemical, and biological and medical processes, employment of this concept for high voltage applications to improve insulation performance as an alternative to the pressurized gas-insulated systems (gis) utilizing ...

Wind powers are very unstable in voltage fluctuations, especially in short circuit error and sharp and sudden voltage drops, which one of its main reasons is the use of induction generators in these power plants and thus need to reactive power and high magnetizing current. To improve the ride_through voltage from WECS in error conditions and damping the oscillations of the induction generator r...

A. Arora A. K. Dubey R. Agarwal R. Sharma

Capacitive Micro-machined Ultrasonic Transducers (CMUTs) are the ultrasonic devices which produce better features in contrast to piezoelectric transducers. The intrinsic parameter of CMUT varies with the variation in geometrical dimension of the device. The cavity height and the radius of the CMUT with circular membrane is varied in the lumped parallel plate model for its impact on the paramete...

The Dynamic Voltage Restorer (DVR) is a commercially available, popular device to eliminate voltage sags and swells in the distribution lines. Its basic function is to inject the voltage difference (difference between the pre-sag and sag voltage) to the power line and maintains the pre-sag voltage condition in the load side. The efficiency of the DVR depends on the performance of the efficiency...

Arash Tavighi Hassan Monsef Saeed Afsharnia

Today, with attention to increase in sensitive electrical equipments application in distribution networks and their susceptibility to the power quality deficiencies, the protection necessity of sensitive loads against undesirable effects of these disturbances are in focus. So, in this paper voltage sag deficiency and Dynamic Voltage Restorer (DVR) would be introduced as the most prevalent power...

2014
Anjali Menon

This paper presents the designing of a low powered (25-30 watts), portable and cost effective solar micro-inverter wherein the single solar panel is able to run the AC loads along with DC loads. The system consists of a solar panel, DC-DC push-pull converter, DC-AC inverter, LC filter and the test loads. The solar cell powers DC-DC push pull converter which boosts the input DC voltage into the ...

Journal: :Transactions on Electrical and Electronic Materials 2016

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید