نتایج جستجو برای: aisi 316l

تعداد نتایج: 5100  

2013
Y. Hedberg X. Wang J. Hedberg M. Lundin E. Blomberg I. Odnevall Wallinder

Implantation using stainless steels (SS) is an example where an understanding of protein-induced metal release from SS is important when assessing potential toxicological risks. Here, the protein-induced metal release was investigated for austenitic (AISI 304, 310, and 316L), ferritic (AISI 430), and duplex (AISI 2205) grades in a phosphate buffered saline (PBS, pH 7.4) solution containing eith...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه تربیت مدرس - دانشکده مهندسی 1393

در این پژوهش به بررسی اثر فرایند همزن اصطکاکی در سرعت های دورانی پایین بر ریزساختار و خواص مکانیکی فولاد زنگ نزن آستنیتی aisi 316l پرداخته می شود.

Ch. Dehghanian H. Mirzadeh M. J. Sohrabi

Microstructural evolutions during annealing of cold rolled AISI 304L and AISI 316L stainless steels were studied. Cold rolled AISI 304L alloy was fully martensitic but cold rolled AISI 316L alloy was partially martensitic due to the higher stability of the austenite phase in the latter. During continuous heating to elevated temperatures, the complete reversion of strain-induced martensite at 75...

2017
A. Hedayati E. Vuorinen

In the polymer electrolyte membrane fuel cells (PEMFCs), low corrosion resistance and high interfacial contact resistance (ICR) are two controversial issues in usage of AISI 316L stainless steel as a metallic bipolar plate. For solving these problems, investigation and development of different coatings and/or surface treatments are inevitable. Corrosion behavior and ICR of AISI 316L specimens c...

2013
Witold WALKE Joanna PRZONDZIONO

The purpose of the study was evaluation of corrosion resistance of steel 316L used in cardiologic treatment mainly for vascular stents. The study analysed influence of electrochemical and chemical treatment of the steel surface, including sterilisation with pressurised water steam, on its corrosion characteristics. The tests were performed in artificial blood plasma simulating human blood envir...

2015
Sabrina Tardio Marie-Laure Abel Robert H. Carr James E. Castle John F. Watts

The very thin native oxide film on stainless steel, of the order of 2 nm, is known to be readily modified by immersion in aqueous media. In this paper, XPS and ToF-SIMS are employed to investigate the nature of the air-formed film and modification after water emmersion. The film is described in terms of oxide, hydroxide and water content. The preferential dissolution of iron is shown to occur o...

2013
Erfan Salahinejad Mohammad Jafar Hadianfard Digby Donald Macdonald Samin Sharifi-Asl Masoud Mozafari Kenneth J. Walker Armin Tahmasbi Rad Sundararajan V. Madihally Lobat Tayebi

The corrosion and cell viability behaviors of nanostructured, nickel-free stainless steel implants were studied and compared with AISI 316L. The electrochemical studies were conducted by potentiodynamic polarization and electrochemical impedance spectroscopic measurements in a simulated body fluid. Cytocompatibility was also evaluated by the adhesion behavior of adult human stem cells on the su...

Journal: :Journal of microscopy 2016
Dhanya Ramachandran Ricardo Egoavil Amandine Crabbe Tom Hauffman Artem Abakumov Johan Verbeeck Isabelle Vandendael Herman Terryn Dominique Schryvers

The chemical composition, nanostructure and electronic structure of nanosized oxide scales naturally formed on the surface of AISI 316L stainless steel microfibres used for strengthening of composite materials have been characterised using a combination of scanning and transmission electron microscopy with energy-dispersive X-ray, electron energy loss and Auger spectroscopy. The analysis reveal...

2009
Tadeusz Hryniewicz Krzysztof Rokosz Massimiliano Filippi

The polarisation characteristics of the electropolishing process in a magnetic field (MEP – magnetoelectropolishing), in comparison with those obtained under standard/conventional process (EP) conditions, have been obtained. The occurrence of an EP plateau has been observed in view of the optimization of MEP process. Up-to-date stainless steel surface studies always indicated some amount of fre...

2017
Jean Geringer Bernard Forest Pierre Combrade

Wear of Poly (Methyl MethAcrylate), PMMA, against a metallic surface, AISI 316L stainless steel, SS, has been investigated in dry conditions. These materials have been used to simulate the degradation of the contact, femoral stem-bone cement in the field of hip prosthesis. First of all, no significant wear was observed on the 316L SS. PMMA wear has been quantified: the energy wear coefficient, ...