نتایج جستجو برای: current transformer elimination
تعداد نتایج: 838563 فیلتر نتایج به سال:
Low- impedance transformer ground differential relay is a part of power transformer protection system that is employed for detecting the internal earth faults. This is a fast and sensitive relay, but during some external faults and inrush current conditions, may be exposed to maloperation due to current transformer (CT) saturation. In this paper, a new intelligent transformer ground differentia...
چکیده ندارد.
Energizing of large power transformers is considered a critical event in the operation of an electric power system. When a transformer is energized by the grid or utility, it takes very high value current known as inrush current, the typical value of this current could be ten times. This inrush causes many problems like mechanical stress on transformer & harmonics injection to generator winding...
A concern with the isolation transformer in a dual active bridge (DAB) dc–dc converter is dc bias magnetization. This article proposes fluxgate-based current sensor to measure component mixed large, high-frequency ac current. Compared commercial Hall effect sensor, proposed significantly reduces measurement error. presents working principle and design considerations. prototype demonstrated for ...
The behavior of three phase five leg transformer under voltage sag is studied in this paper. This paper proposes a simple, practical model of a three phase-five leg, saturated transformer with accurate performance. Transformer saturation is produced when the voltage sag is recovered and it causes inrush current in transformer. Effects of voltage sag depth, duration and initial point on wave hav...
DC bias current flowing into the neutral point of power transformer will seriously affect the normal operation of AC power system. In this paper, exciting current, harmonic component of the excitation current, magnetic flux density and noise of transformer were analyzed when the transformer is in the no-load operation state based on field-circuit coupled method. Through the calculation and anal...
Eliminating the leakage current is one of most important issues for transformer less inverters in grid connected photovoltaic applications. The technical challenge is how to keep the common mode voltage constant to reduce the leakage current. For this purpose an improved single phase transformer less inverter is proposed. It has two additional switches connected in the dc side. The PWM pulses f...
This paper proposes a new method to detect transformer inside incipient fault current using transformer internal parameters to determine the inside structure of transformer at good condition or bad. A transformer model was established by Jiles– Atherton theory using measured voltage and current and the initial parameters which were found using Genetic Algorithm (GA). Then, transformer internal ...
چکیده ندارد.
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید