نتایج جستجو برای: glass membrane electrode

تعداد نتایج: 516981  

E. Baghdar M. Darvishpour M.H. Fekri

A poly(vinyl chloride) membrane based on a new a-dioxime derivative as membrane carrier was prepared andinvestigated as a Cr(III) selective electrode. The electrode exhibits a good potentiometric response for Cr(III)over a wide concentration range 1.0 x 10-6 to 1.0 x 10-1 M with a slope 19.5+0.5 mV/decade and low detectionlimit of 8.9 x 10-7 M. It has a fast response time < 15 s. The best perfo...

Journal: :journal of physical & theoretical chemistry 2007
masoud giahi mohammad ali bagherinia azin azari

sol-gel and polymeric membrane electrodes, based on thiacalix[4]arene as a neutral carrier, weresuccessfully developed for the detection of vo2+ in aqueous solutions. the sol-gel and pvcmembrane electrodes exhibited linear response with nernstian slopes of 29.3 and 28.4 mv perdecade, respectively, within the vanadyl ion concentration ranges from 1.0 × 10-6 to 1.0 × 10-1mol dm-3 and from 1.0 × 1...

Journal: :journal of physical & theoretical chemistry 2008
n. farahani h. aghaie

fe2+ ion-selective membrane sensor has been fabricated from polyvinyl chloride (pvc) matrixmembrane containing neutral carrier tetra phenyl porphyrin (tpp) ionophore. the addition ofsodium tetraphenylborate (natpb) and the plasticizer dbp has been found to substantiallyimprove the performance of the sensor. the best performance was obtained with the sensor havinga membrane of composition of tpp...

Journal: :Cancer research 1948
K A MEYER E M KAMMERLING

On the basis of extensive studies, it has long been contended by many investigators that the hydrogen ion concentration of malignant tissues differs from that of normal tissues in a characteristic way. The results obtained, however, are highly controversial. Many workers have found an alteration of pH to the alkaline side (1, 4, 5, 9, 14, 16). Others have found an alteration to the acid side (7...

M. Darvishpour M. H. Fekri

A PVC membrane Ni(II) ion selective electrode has been constructed using (1E,2E)-bis(2-aminophenyl)N'1,N'2-dihydroxyethanebis as membrane carrier. The electrode exhibited a goodpotentiometric response for Ni(II) over a wide concentration range 1.0×10-4 to 1.0×10-1M with aslope of 29.4±0.5 mV/decade a and a working pH range of 6.5-9.0. It had a fast response time of≤20s. The best performance was...

H. Aghaie K. Zare M. Aghaie M. Arvand M. H. Felcri

A PVC membrane Cr(III) ion selective electrode has been constructed using 2H-1,4-benzothioazine-2,3(4H)dione dioxime (BTD) as membrane carrier. The influence of membrane composition on the electroderesponse was studied. The electrode exhibits a Nernstian response over a Cr(III) concentration range of 1.0 x10 6 to 1.0>< 10-1 M (r = 0.99) with a slope of 19.5 ± 0.5 mV per decade of concentration,...

This paper proposes a Micro-electro-mechanical (MEMS) capacitive pressure sensor that relies on the movable electrode displaced like a flat plate equal to the maximum center deflection of diaphragm. The diaphragm, movable electrode and mechanical coupling are made of polysilicon, gold and Si3N4, respectively. The fixed electrode is gold and the substrate is Pyrex glass. This proposed method inc...

2010
Muhammad H. Asif Omer Nur Magnus Willander Peter Strålfors Cecilia Brännmark Fredrik Elinder Ulrika H. Englund Jun Lu Lars Hultman

This paper presents the growth and structure of ZnO nanorods on a sub-micrometer glass pipette and their application as an intracellular selective ion sensor. Highly oriented, vertical and aligned ZnO nanorods were grown on the tip of a borosilicate glass capillary (0.7 µm in diameter) by the low temperature aqueous chemical growth (ACG) technique. The relatively large surface-to-volume ratio o...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه رازی - دانشکده علوم 1389

fluorescence chemical sensors for the highly sensitive and selective determination of pb2+ , hg2+, co2+ and fe3+ ions in aqueous solutions are described. the ion sensing system was prepared by incorporating lipophilic ligand (l) as a neutral ion-selective fluoroionophore in the plasticized pvc membrane containing sodium tetraphenylborate or potasium tetrakis (p-chlorophenyl) borate as a liphoph...

Journal: :journal of petroleum science and technology 2013
mostafa dehghani mobarake ramin karami

in the present study, a new gas diffusion electrode (gde) (based on pt/nafion membrane) is fabricated. the electrochemical results show that the new gde has the highest electrochemical activity toward the oxygen reduction reaction (orr) among the three electrodes. the sem and xrd findings show that a platinum layer can be attached to nafion membrane closely and firmly with a strong peak corresp...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید