نتایج جستجو برای: patient dose in ct

تعداد نتایج: 17096387  

Journal: :iranian journal of medical physics 0
peyman hejazi medical physics dept., semnan university of medical sciences, semnan, iran

introduction in computed tomography (ct) technology, an optimal radiation dose can be achieved via changing radiation parameters such as ma, pitch factor, rotation time and tube voltage (kvp) for diagnostic images. materials and methods in this study, the brain, abdomen, and thorax scaning was performed using toshiba 16-slice scannerand standard aapm and ctdi phantoms. aapm phantom was used for...

Journal: :iranian journal of medical physics 0
mostafa robatjazi ph.d student of medical physics, medical physics dept., faculty of medicine, tehran university of medical sciences, tehran, iran seyed rabie mahdavi assistant professor, medical physics dept., faculty of medicine, tehran university of medical sciences, tehran, iran bahram bolouri assistant professor, radiation oncology dept., faculty of medicine, tehran university of medical sciences, tehran, iran alireza nikoofar assistant professor, radiation oncology dept., faculty of medicine, tehran university of medical sciences, tehran, iran

introduction: recently, magnetic resonance spectroscopic imaging (mrsi), as a functional imaging method, has been used for clinical target volume definition. in this study, we used this method to define the target volume in prostate radiotherapy. material and method: in this study, we used images of 20 prostate cancer cases. mrsi and mri images were fused with ct images. then, treatment plannin...

Alireza Nikoofar Bahram Bolouri Mostafa Robatjazi Seyed Rabie Mahdavi,

Introduction: Recently, magnetic resonance spectroscopic imaging (MRSI), as a functional imaging method, has been used for clinical target volume definition. In this study, we used this method to define the target volume in prostate radiotherapy. Material and Method: In this study, we used images of 20 prostate cancer cases. MRSI and MRI images were fused with CT images. Then, treatment plannin...

Journal: :journal of biomedical physics and engineering 0
s zargan department of medical physics, babol university of medical sciences, babol, iran p ghafarian chronic respiratory diseases research center, national research institute of tuberculosis and lung diseases (nritld), shسازمان اصلی تایید شده: دانشگاه علوم پزشکی بابل (babol university of medical sciences)سازمان های دیگر: pet/ct and cyclotron center, masih daneshvari hospital, shahid beheshti university of medical sciences, tehran,

background: pet/ct imaging using [18f]-fdg is utilized in clinical oncology for tumor detecting, staging and responding to therapy procedures. essential consideration must be taken for radiation staff due to high gamma radiation in pet/ct and cyclotron center. the aim of this study was to assess the staff exposure regarding whole body and organ dose and to evaluate environment dose in pet/ct an...

آهنگر, نعمت الله , جان بابایی, قاسم , صالحی فر, ابراهیم, فرهادی, فهیمه,

Background and purpose: The objective of this study was to determine the influence of 3 vitamin K epoxide reductase complex subunit 1 (VKORC1) polymorphisms (-1639G>A, 1173C>T and 3730G>A) on warfarin dose requirement in patients from Mazandaran province, Iran. Materials and methods: A total of 29 patients taking warfarin for at least 3 months and had stable dose requirements were enrolled i...

ژورنال: سنجش و ایمنی پرتو 2020

SPECT-CT is an imaging method for diagnosing diseases and studying physiology of the body. In this type of imaging, due to the use of radiopharmaceutical for imaging (SPECT) and X-rays (CT), a relatively high dose of radiation is introduced into the patient. If the patient is pregnant, considering that the developing fetus is sensitive to any radiation in the uterus throughout the entire period...

Journal: :iranian journal of radiology 0
lukas lambert department of radiology, first faculty of medicine, charles university in prague, prague, czech republic; department of radiology, general university hospital in prague, u nemocnice 2, 128 08 prague 2, czech republic. tel: +420-224962232, fax: +420-224963048 alena lambertova department of radiology, first faculty of medicine, charles university in prague, prague, czech republic; department of psychiatry, first faculty of medicine, charles university in prague, prague, czech republic jan danes department of radiology, first faculty of medicine, charles university in prague, prague, czech republic gabriela grusova fourth department of internal medicine, first faculty of medicine, charles university in prague, prague, czech republic

conclusion we constructed and validated a ct colonography phantom with correct density allowing performance of reproducible experiments. materials and methods we found 15 different phantom designs by literature search and compared their advantages and disadvantages based on their description and images. we tested various materials for density and mechanical properties and constructed a phantom ...

Haddadi, Gholamhosein, Haddadi, Mohammad Bagher, Mehdizadeh, Simin, Meshkibaf, Mohammad Hasan,

Background & Objectives: Computed tomography (CT) represents 11% of all diagnostic radiology procedures but it contributes to almost 67% of the total effective dose to the human population. In head and neck CT which consist of 1/3 of total CT scans, other critical organs such as lenses and thyroid are in the radiation field. Also in the abdomen and pelvis scan, irradiation of ovaries is unavoid...

2004
P C Shrimpton

This report summarises work undertaken in support of a European Commission (EC) Concerted Action on CT that has included both a review and further development of the framework for CT dosimetry. The system previously established by the EC for reference doses in CT (with the quantities weighted CTDI (CTDIw) and dose-length product (DLP)) has been expanded to include subsequent developments in CT ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید