نتایج جستجو برای: potentiometry ion selective membrane electrode
تعداد نتایج: 802881 فیلتر نتایج به سال:
The potentiometric response characteristics and analytical applications of a poly(vinyl chloride) (PVC)-free all-solid-state ion-selective electrode for chlorhexidine (CHX) are examined and compared to those of PVC-based solid-state electrode. The PVCfree electrode is prepared by direct incorporation of chlorhexidine-tetraphenyl borate (CHXTPB) as a sensing element into a commercial nail varnis...
در این پایان نامه جهت اندازه گیری پتانسیومتری کاتیونهای سرب pb2+ و نیکلni2+ ، الکترود یون گزین غشایی مبتنی بر پلی وینیل کلرید (pvc) و الکترودهای خمیر کربن با استفاده از دو یون دوست جدید به همراه نرم کننده و افزودنیهای یونی طراحی، ساخت و مورد بررسی قرار گرفت. در تهیه الکترود یون گزین سرب از لیگاند n,n بیس( سالیسیلیدین) 1و6 دی آمینو هگزان (nsah) در ترکیب الکترود خمیر کربنی استفاده شد. الکترود ف...
potentiometric investigation on {h2o+nano3+peg1500} mixtures were made at t=308.15k, using electrochemical cells with two ion-selective electrodes, (na+ glass) as the cation ion-selective electrode against (no3- solvent-polymer pvc) as the anion ion-selective electrode. the mean ionic activity coefficients of nano3 were measured at different concentrations of nano3 and peg. maximum concentrati...
In order to preparing strontium ion selective electrode 6-(4- nitropheny1)-2-pheny14, 4- dipropy1-3, 5-diaza-bicyclo [3, 1, 0] hex-2-ene (NPDBH) was used as an ionophore. This electrode responds to Sr (II)ion with a sensitivity of 28.2 ± 0.5 mV/decade over the range 1.0 x 10-6 to 1.0 Mat pH 3.0-10.0. Thelimit of detection was 2.4 x 10-7 M. The influences of membrane composition, the pH of the t...
چکیده ندارد.
چکیده ندارد.
a highly selective electrode for bromide ion based on aza pyrilium derivative as an excellentionophore is described.the sensor exhibits a good linear response with a slope of ( 60±1 ) mv per decadeover the concentration range of ( 1×10-3 – 9×10-6 m ) , and a detection limit of ( 3×10-6 m ) of bromideions .the electrode response is independent of ph in the range of(4.0 –9.5).selectivity coeffici...
Sol-gel and polymeric membrane electrodes, based on thiacalix[4]arene as a neutral carrier, weresuccessfully developed for the detection of VO2+ in aqueous solutions. The sol-gel and PVCmembrane electrodes exhibited linear response with Nernstian slopes of 29.3 and 28.4 mV perdecade, respectively, within the vanadyl ion concentration ranges from 1.0 × 10-6 to 1.0 × 10-1mol dm-3 and from 1.0 × 1...
A new selectophore was introduced for Cu2+ ions. Spectroscopic studies showed a selectivity of a new organic compound (L) toward copper ions and several transitional metal ions. Hence, L was utilized in designing several ion selective electrodes for these cations. In practice, Cu2+ ion selective electrode behaved Nernstian (slope of 27.95±0.3 mV decade-1) over a...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید