An intelligent method based on wavelet neural network (WNN) is presented in this study to estimate voltage harmonic distortion waveforms at a non-monitored sensitive load. Voltage harmonics are considered as the main type of waveform distortion in the power quality approach. To detect and analyze voltage harmonics, it is not economical to install power quality monitors (PQMs) at all buses. The ...

2015
Mr. B. Rajesh

This paper presents a Selective Harmonic Elimination-PWM technology (SHE-PWM) employing H-Bridge multilevel inverter configuration. In this method variable DC voltage is used and the lower order harmonics are eliminated, without affecting the structure of the inverter. This method gives constant switching angle, so it reduces the number of steps required for offline calculation. The proposed me...

2015

There is growing interest in renewable energy around the world. Since most renewable sources are intermittent in nature, it is a challenging task to integrate renewable energy resources into the power grid infrastructure. Distribution systems provide standby service during utility outages and when operated during peak load hours, potentially reduce energy costs. This paper presents a grid inter...

2012
K Hussain J Praveen

In this paper, a new three-phase four-wire distribution static compensator (DSTATCOM) based on a T-connected transformer and a three-leg voltage source converter (VSC) is proposed for power quality improvement. The T-connected transformer connection mitigates the neutral current and the three-leg VSC compensates harmonic current, reactive power, and balances the load. Two single-phase transform...

2013
Kuldeep Singh Bedi

This paper presents a control scheme which controls in which PV (Photovoltaic) and Fuel cell system are connected through a DC bus. In order to achieve maximum utilization of distribution generation, power supplied to load for day and night through renewable resources. PV power availability is depends upon the solar irradiation so that it becomes important to extract maximum possible power from...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه شیخ بهایی - دانشکده زبانهای خارجی 1391

phatic communion is a cultural concept which differs across cultures. according to hofstede (2001), the u.s. tends to have individualistic culture; however, asian countries tend to have collectivistic cultures. these cultures view phatic communion differently. in individualistic cultures like u.s., phatic communion reflects speakers’ socio-cultural relationships in conversations. to see whether...

This paper presents a novel method to calculate the reference source current and the referencecompensating current for shunt active power filters (SAPFs). This method first calculates theamplitude and phase of the fundamental load current from a recursive algebraic approach blockbefore calculating the displacement power factor. Next, the amplitude of the reference mains currentis computed with ...

2014
R. Balaji B.Mohamed Faizal

This paper presents a active filter topology and its control technique. Active power filter topology is the most efficient way to compensate reactive power and lower order harmonics generated by non linear loads. The shunt active power filter was consider to be the most basic configuration for the APF. Different techniques have been applied to obtain a control signal for the active filters. One...

Journal: :the modares journal of electrical engineering 2010
abdol ali - abdipour mohammad hakkak zahra ghanian

the graphical technique for nonlinear circuits was described that enable us to optimize circuits to obtain maximum output power, maximum efficiency or minimum intermodulation. according to this method a high power amplifier in the ka band was designed. using a nonlinear model of the transistor, optimum slope for load-line was determined so that maximum power at the output was obtainable, then ...

Journal: :journal of artificial intelligence in electrical engineering 0

this paper presents a novel method to calculate the reference source current and the referencecompensating current for shunt active power filters (sapfs). this method first calculates theamplitude and phase of the fundamental load current from a recursive algebraic approach blockbefore calculating the displacement power factor. next, the amplitude of the reference mains currentis computed with ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید