نتایج جستجو برای: کد mcnp4c

تعداد نتایج: 6528  

احمدی, ام لیلا, توکلی عنبران, حسین,

Introduction: The dosimetry of the brachytherapy sources is performed in the water source medium according to protocol TG-43U1. To achieve a resonable results on treatment, the use of the water material for all body tissues can be one of the faulty sources in delivering the correct dose to the tumor. Thus, we have focused on the dosimetry parameters in fat density 0.95 gr/cm3 and the muscle wit...

2002
Hamid Tagziria Neil Roberts Andrew Bennett David J Thomas Martyn Sené

An extensive programme was successfully carried out during the 1995 to 1998 NMS programme to recalibrate and model by Monte Carlo simulations the characteristics of two NPL long counters that are routinely used to standardise neutron fluences [Ta98,Ta00] for neutron energies above 500 keV. The present work is a continuation of it in that the counters responses and effective centres have been me...

2013
Rahim Khabaz Reza Izadi Najafabadi R. I. Najafabadi

This paper presents the evaluation of the geometry correction factor for calibration of Bonner sphere spectrometer (BSS) equipped with the He counter (typical SP9), based on Monte Carlo simulation. Using the MCNP4C code, geometry factors and effectiveness parameters (d) of a 800 polyethylene sphere (r = 10.16 cm) were calculated for 10 different energies and 3 various distances between the sour...

2014
PARISA AKHLAGHI LALEH RAFAT-MOTAVALLI SEYED HASHEM MIRI-HAKIMABAD

The term ‘thermal flux’ implies a Maxwellian distribution of velocity and energy corresponding to the most probable velocity of 2200 m s−1 at 293.4 K. In order to measure the thermal neutron flux density, the foil activation method was used. Thermal neutron flux determination in paraffin phantom by counting the emitted rays of indium foils with two different detectors (Geiger– Muller counter an...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه صنعتی اصفهان - دانشکده ریاضی 1392

این پایان نامه ساخت و آنالیز کدهای دوری و شبه دوری، به خصوص کدهای با ماتریس بررسی-‎‎توازن خلوت ldpc را در نظر می گیرد. ‏ در این پایان نامه ‎ابتدا‎‎‎‎ نشان داده می شود، یک کد دوری با ماتریس بررسی-توازن به شکل چرخشی، می تواند منشأ تولید کدهای دوری و شبه دوری qc‎ با طول و نرخ متفاوت شود. بسیاری از ویژگی های ساختاری اساسی این دسته از کدهای تولید شده، از قبیل ریشه های چندجمله ای مولد آن ها، به د...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه تحصیلات تکمیلی علوم پایه زنجان - دانشکده ریاضی 1390

هدف این پایان نامه، معرفی و بررسی خوریختی های کدهای هندسه جبری و ارتباط آن با خودریختی های میدان توابع جبری است. از آنجا که از دید رسته ای میدان توابع جبری هم ارز با برخی ساختارهای جبری دیگر نظیر سطوح ریمان هستند، یافتن ارتباط بین این دو دسته خودریختی می تواند کمک زیادی در شناسایی خودریختی های کدها و در نتیجه رده ی بزرگی از کدها شامل کدهای دوری باشد. لذا در این پایان نامه پس از معرفی کد، میدان ...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه الزهراء - دانشکده علوم پایه 1388

فرض کنید g یک گراف با مجموعه رِِِأسهای v و مجموعه یالهای e باشد. زیرمجموعه s از رأسهای g را مجموعه احاطه گر می گویند هر گاه هر رأس vs با حداقل یک رأس از s مجاور باشد.زیرمجموعه s را احاطه گر تام می گویند اگر هر رأس از v با حداقل یک رأس از s مجاور باشد. اگر در تعاریف این مجموعه ها بجای کلمه حداقل از کلمه دقیقاٌ استفاده کنیم مجموعه های مذکور را به ترتیب کد کامل و کدتام کامل می نامند. اگر تعریف کد کامل...

Journal: :iranian journal of radiation research 0
m. momennezhad nuclear medicine research center, emam reza hospital, mashhad university of medical sciences, mashhad, iran m.t. bahreyni toosi medical physics research center, mashhad university of medical sciences, mashhad, iran r. sadeghi nuclear medicine research center, emam reza hospital, mashhad university of medical sciences, mashhad, iran h. gholamhoseinian department of medical physics, medical school, mashhad university of medical sciences, mashhad, iran sh. nasseri department of medical physics, medical school, mashhad university of medical sciences, mashhad, iran

background: the presence of a wedge filter in the beam trajectory can modify the beam quality and cause some changes in the dosimetry parameters which are usually difficult to be measured directly and accurately. material and methods: in this study the mcnp-4c monte carlo code was used to simulate the 9 mv photon beam generated by a linear accelerator. upon getting a good agreement between the ...

ژورنال: :سنجش و ایمنی پرتو 0
صفرعلی صفری safar ali safari amirkabir university of technologyدانشگاه صنعتی امیرکبیر مجتبی شمسائی ظفرقندی mojtaba shamsaei zafarghandi amirkabir university of technologyدانشگاه صنعتی امیرکبیر رضا اسدنژاد reza asadnejad amirkabir university of technologyدانشگاه صنعتی امیرکبیر

یکی از اصولی ترین و اساسی ترین ویژگی آزمایشگاه های هسته ای که باید مورد توجه قرار بگیرد، ایمنی پرتو ها و ملاحظات مربوط به فیزیک بهداشت است. در این مقاله، با بررسی موردی یک آزمایشگاه تحقیقاتی فعال در حوزۀ مطالعات هسته ای واقع در دانشگاه صنعتی امیرکبیر، بر آن شدیم تا با تعیین میزان نرخ دز جذبی در نواحی مختلف آزمایشگاه، نواحی پرخطر یا امن آن را شناسایی کنیم و طبق معیار های استاندارد فیزیک بهداشت و...

ژورنال: :پژوهش فیزیک ایران 0
علی پذیرنده ali pazirandeh nuclear engineering department, science, research campus azad universityگروه مهندسی هسته ای، واحد علوم و تحقیقات، دانشگاه آزاد اسلامی الهام شکریان elham shekarian nuclear engineering department, science, research campus azad universityگروه مهندسی هسته ای، واحد علوم و تحقیقات، دانشگاه آزاد اسلامی

در درمان غدد سرطانی درون مغزی با روش نوترون درمانی با بور, انرژی بهینه نوترون از نظر درمان, فیزیک نوترون و شیمی مساله, در دهه اخیر مورد مطالعه بوده است گرچه سطح مقطع جذب نوترون حرارتی با بور بالاست( 3836 بارن) لکن برای معالجه غدد درون مغزی نظیر گلیوبلاستوما نیاز به نوترونهای سریع است تا ضمن حرکت به سوی غده حرارتی شوند. از سوی دیگر در برخورد نوترونهای پرانرژی به هسته اتمها به ویژه هیدروژن, باعث ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید