نتایج جستجو برای: acoustic feedback

تعداد نتایج: 232105  

Journal: :auditory and vestibular research 0
fatmah tarrab department of biomedical engineering, faculty of electrical and mechanical engineering, damascus university, damascus, syria zouheir marmar department of biomedical engineering, faculty of electrical and mechanical engineering, damascus university, damascus, syria isam alamine department of otorhinolaryngology, faculty of medicine, damascus university, damascus, syria

background and aim : the hearing loss and acoustic feedback signal in the binaural hearing aids may annoy users, make speech reorganization difficult, and affect the sound quality. this paper presents a new method for acoustic feedback suppression in binaural hearing aids, based on the combination of binaural information and blind source separation. this method can enhance sound from the specif...

2012
Mike Skocik Alexay Kozhevnikov

Studies of behavioral and neural responses to distorted auditory feedback (DAF) can help shed light on the neural mechanisms of animal vocalizations. We describe an apparatus for generating real-time acoustic feedback. The system can very rapidly detect acoustic features in a song and output acoustic signals if the detected features match the desired acoustic template. The system uses spectrogr...

Journal: :IEEE Trans. Speech and Audio Processing 2000
Marcio G. Siqueira Abeer Alwan

Acoustic feedback is a problem in hearing aids that contain a substantial amount of gain, hearing aids that are used in conjunction with vented or open molds, and in-the-ear hearing aids. Acoustic feedback is both annoying and reduces the maximum usable gain of hearing-aid devices. This paper studies analytically the steady-state convergence behavior of LMS-based adaptive algorithms when used i...

2009
Dirk Moelants Michiel Demey Marc Leman

This paper presents a study where the effect of a delayed acoustic feedback is researched with 10 professional musicians performing four different pieces of piano music. The influence of a delayed auditory feedback on the performance is quantified using both MIDI information and the measurement of the movement of the upper body of the pianists. Four conditions were examined namely: a normal pia...

Journal: :The Journal of the Acoustical Society of America 2011
Alexander S Treiber Gerhard Gruhler Gregor Rozinaj

This work investigates the effect of the acoustic feedback of rotary encoders that are common in current human-machine-interfaces. The results are based on subjective trials in which the probands had to complete generic tasks using an encoder with programmable electro acoustic feedback. The tasks had to be performed with individually optimized feedback and two reference conditions. The results ...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه تبریز - دانشکده ادبیات و زبانهای خارجی 1391

abstract this study investigates the teachers’ correction of students’ spoken errors of linguistic forms in efl classes, aiming at (a) examining the relationship between the learners’ proficiency level and the provision of corrective feedback types, (b) exploring the extent to which teachers’ use of different corrective feedback types is related to the immediate types of context in which err...

2012
Meng Guo

Acoustic feedback problems occur when the output loudspeaker signal of an audio system is partly returned to the input microphone via an acoustic coupling through the air. This problem often causes significant performance degradations in applications such as public address systems and hearing aids. In the worst case, the audio system becomes unstable and howling occurs. In this work, first we a...

2011
Christian Herff Matthias Janke Michael Wand Tanja Schultz

This paper reports on our recent research in the feedback effects of Silent Speech. Our technology is based on surface electromyography (EMG) which captures the electrical potentials of the human articulatory muscles rather than the acoustic speech signal. While recognition results are good for loudly articulated speech and when experienced users speak silently, novice users usually achieve far...

2016
Tingting Zhu

A new optimized blind equalization algorithm for sparse underwater acoustic channel is proposed in this paper. The decision feedback equalizer is a common nonlinear equalizer to overcome the effect of noise in underwater acoustic communication. The decision feedback equalizer algorithm tracks the underwater acoustic channel change and utilizes the feedback information to adjust equalizer. The g...

2016
Henning F. Schepker Linh Thi Thuc Tran Sven Nordholm Simon Doclo

To reduce acoustic feedback in hearing aids, adaptive filters are commonly used to estimate the feedback contribution in the microphone(s). While theoretically allowing for perfect feedback cancellation, in practice the solution is typically biased due to the closed-loop acoustical system. For an earpiece with multiple integrated microphones and loudspeakers, we propose to use a fixed beamforme...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید