Journal: :journal of paramedical sciences 0
hamed manoochehri khoshinani department of radiology, faculty of paramedicine, hamadan university of medical science, hamadan, iran samira heidari department of radiology, faculty of paramedicine, hamadan university of medical science, hamadan, iran

repeating x-ray radiographs, as a common problem in radiology units, represent additional, non-billable costs due to increased film, chemistry, and equipment use as well as increased personnel time. furthermore, patients receive additional radiation exposure from repetitions and must remain on the premises until the second exam is completed. compounding the overt negative financial impact on th...

Journal: :iranian journal of radiation research 0
v. changizi department of radiology technology, school of allied medical sciences, tehran university of medical sciences, tehran, iran e. jazayeri department of radiology technology, school of allied medical sciences, tehran university of medical sciences, tehran, iran a. talaeepour department of oral radiology, school of dentistry, tehran university of medical sciences, tehran, iran

abstract background: the radiographic image accuracy depends on the x-ray film information visibility. good visibility is found by good contrast. radiation exposure parameters (kvp, mas) and film processing conditions have impact on contrast. in dentistry radiography machines, exposure time and processing procedure are set by radiographer. no optimized exposure time and processing conditions ma...

Journal: :journal of paramedical sciences 0
maryam mojiri radiology department, paramedical school, hamadan university of medical science, hamadan karim ghazi khanloo sani radiology department, paramedical school, hamadan university of medical science, hamadan abbas moghim beigi department of biostatistics and epidemiology, research center for health sciences, hamadan university of medical science, hamadan

the aim of this study is to compare the sensitometric properties of commonly used radiographic films processed with chemical solutions in different workload hospitals. the effect of different processing conditions on induced densities on radiologic films was investigated. two accessible double emulsions fuji and kodak films were exposed with 11-step wedge and processed with champion and cpac pr...

Background and purpose: Radiographic film repeat rate assessment is performed to appropriate profiting of existence resources in therapeutic wards. Multiple exposures of x-ray generators due to repeated radiographic examination can lead to amortization of the radiographic facilities and decrease their longevity and also increases the cost of facilities repair. On the other hand, its therapeut...

2011
Hiroshi Muto Yuji Tani Shigemasa Suzuki Yuki Yokooka Tamotsu Abe Yuji Sase Takayoshi Terashita Katsuhiko Ogasawara

BACKGROUND Since the shift from a radiographic film-based system to that of a filmless system, the change in radiographic examination costs and costs structure have been undetermined. The activity-based costing (ABC) method measures the cost and performance of activities, resources, and cost objects. The purpose of this study is to identify the cost structure of a radiographic examination compa...

ژورنال: مجله دندانپزشکی 2019
Ahmadian Yazdi, Azam , Moghaddam, Hosein Saeedi , Mortazavi, Samareh ,

Background and Aims: Dental diagnosis may be affected by the occurrence of the errors in the intra-oral radiographic images and the patients’ treatment plan can be problematic in these cases. The repetition of these radiographs increases the risks of radiation exposure for the patients in turn. The present study assessed the incidences of common periapical radiographic errors taken by dental st...

Journal: :Physics in medicine and biology 2003
Tsang Cheung Peter K N Yu Martin J Butson

Kodak X-Omat V radiographic film has been tested for its polarization properties when using polarized and non-polarized light sources and detectors. The radiographic film has been shown to produce a relatively small but not negligible (less than 5%) variation in 90 degrees cycles in measured optical density within the visible spectrum when the light source is fully linear polarized and the film...

Journal: :Physics in medicine and biology 2003
Martin J Butson Peter K N Yu Tsang Cheung

Multi-leaf penumbral doses have been investigated for 6 MV x-rays and a Varian millennium multi-leaf collimator (MLC) using Gafchromic MD-55-2, radiochromic film and X-omat V radiographic film. An advantage of Gafchromic film for multi-leaf penumbral dose measurement is the relatively low energy dependence of the film. A comparison of penumbral dose measurements has also ascertained the effects...

Farida Abesi , Fatemeh Baghbani, Sina Haghanifar, Soraya Khafri,

Introduction: Dental caries is dramatically common among people. The aim of this study was to evaluate the agreement of paper prints and film prints and monitor in detection of dentinal caries in digital panoramic radiography. Materials and methods: In this analytical study, radiographic images of 150 patients referred to a private clinic and who needed panoramic radiographs for various rea...

فلاح محمدی , غلامرضا, یوسفی, سهراب,

Abstract Background and purpose: The Commission of European Communities (CEC) has developed a guideline in which many common radiographic techniques are determined. Following these guidelines will reduce patient dose and good quality image is obtained. Noncompliance of radiographic centers with standard guidelines not only leads to reduction in radiographic image quality but also wastes reso...