Dosimetric Evaluation of Target Volume in Breast Boost Radiotherapy: Comparison of Electron and Photon Beam

نویسندگان

  • Pourfallah, Tayyeb Associate Professor, Department of Biochemistry, Biophysics & Genetics, Faculty of Medicine, Mazandaran University of Medical Sciences, Sari, Iran
  • Seifi Makrani, Danial Msc in Medical Physics, Faculty of Medicine, Mazandaran University of Medical Sciences, Sari, Iran
  • Shahidi, Maryam Assistant Professor, Department of of Biochemistry, Biophysics & Genetics,, Faculty of Medicine, Mazandaran University of Medical Sciences, Sari, Iran
چکیده مقاله:

Background and purpose: Breast‑conserving surgery followed by radiation therapy to the whole breast is now recognized as a standard strategy in patients with breast cancer. Recommended technique for radiotherapy is whole breast irradiation followed by boost to the tumor bed. This study aimed to compare the dosimetric parameters of electron and photon beams for boosting irradia­tion in post‑lumpectomy patients of breast cancer. Materials and methods: This analytical study included 50 patients of post‑lumpectomy breast cancer. Treatment Planning System (TPS) was used to compare the plans for electron beam and photon beam boost irradiation. The organs at risk (OAR) consist of heart, ipsilateral lung, and skin. Target-volume coverage, Conformity Index (CI), Homogeneity Index (HI), and doses to OAR were compared. Results: Photon plans represented a considerably better CI and HI for the planning target volumes (PTV), compared to the electron beam plans. Regarding OAR sparing, the V1Gy and Dmean in heart and ipsilateral lung with photon beam were significantly higher than electron beam (P<0.05). Conclusion: Dosimetric analysis revealed that CI index, HI index, and PTV coverage were significantly better in photon boost plans, while OAR dosimetry conveyed a significant reduction in ipsilateral lung and heart doses with electron beam plans.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of “heart and lung volume absorbed dose” between electron and photon boost radiotherapy after breast conserving surgery

Background: Breast conserving surgery (BCS) followed by radiotherapy (RT) has been widely accepted as the standard treatment in early stages of invasive breast cancer. The standard technique of RT includes whole breast irradiation (WBI). Additional tumor bed boost irradiation has also an important role in the local tumor control. But there are various controversial delivery methods. The aim of ...

متن کامل

Comparison of two radiation techniques in breast boost delivery

Introduction: In the treatment of breast cancer, breast conserving surgery (BCS) and whole breast irradiation is a usual technique. The influence of lumpectomy boost following breast radiotherapy is apparent, but there are different delivery methods. This work intended to compare the dosimetric parameters of electron beams and photon beams for boosting irradiation in breast can...

متن کامل

Dosimetric comparison of whole breast radiotherapy using field in field and conformal radiotherapy techniques in early stage breast cancer

Background: We aimed to compare field-in-field technique (FIF) with conformal tangential field radiotherapy (CRT) in terms of dosimetric benefits for early stage breast cancer radiotherapy. Materials and Methods: Twenty consecutive left-side breast cancer patients who underwent breast-conserving surgery were included to the study. For each patient, two different treatment plans were cr...

متن کامل

Breast Boost: Are We Missing the Target? A Dosimetric Comparison of Two Boost Techniques

Received July 19, 2002; revision received September 16, 2002; accepted September 24, 2002. BACKGROUND. Randomized trials have shown improved local control with the use of a breast boost for patients given breast-conserving treatment for breast carcinoma. Although the use of a breast boost is routine practice, no standard technique has been established. The authors compared the commonly used cli...

متن کامل

Breast Conserving Treatment for Breast Cancer: Dosimetric Comparison of Sequential versus Simultaneous Integrated Photon Boost

BACKGROUND Breast conserving surgery followed by whole breast irradiation is widely accepted as standard of care for early breast cancer. Addition of a boost dose to the initial tumor area further reduces local recurrences. We investigated the dosimetric benefits of a simultaneously integrated boost (SIB) compared to a sequential boost to hypofractionate the boost volume, while maintaining norm...

متن کامل

Uniformity of Dose Distribution in Target Volume in Radiotherapy Techniques for Breast after Mastectomy.

Background & Objective: Radiotherapy has a very special significance in the treatment of cancer. Beam radiation therapy using photons and electrons produced by a linear accelerator is used extensively in the treatment of breast Cancer. In this article, In addition to providing a description of three techniques of radiotherapy in the treatment of breast cancer, has been Evaluating the effectiven...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 29  شماره 175

صفحات  65- 75

تاریخ انتشار 2019-08

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

کلمات کلیدی برای این مقاله ارائه نشده است

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023