نتایج جستجو برای: dose distribution comparison
تعداد نتایج: 1462848 فیلتر نتایج به سال:
Verification of Varian enhanced dynamic wedge implementation in MasterPlan treatment planning system
This paper investigates the accuracy of the two available calculation algorithms of the Oncentra MasterPlan three-dimensional treatment planning system (TPS)-- the pencil beam method and collapsed-cone convolution--in modeling the Varian enhanced dynamic wedge (EDW). Measurements were carried out for a dual high energy (6-15 MV) Varian DHX-S linear accelerator using ionization chambers for beam...
background :wide distribution and low half-life of acyclovir has led to a high dose consumption of the drug. recent studies have shown that encapsulation of acyclovir in nano-carriers can increase effectiveness and decrease its side effects. we investigated the inhibitory effect of acyclovir loaded nano-niosomes against herpes simplex virus type-1 (hsv-1) in cell culture. methods : in-vitro c...
Background and purpose: Radiation therapy make an important contribution in the control and treatment of cancers. Lungs are the main organs at risk in esophageal cancer radiotherapy. Difference between the dose distribution due to the treatment planning system (TPS) and the patient's body dose is dependent on the calculation of the treatment planning system algorithm, which is more pronounced i...
PURPOSE New multidimensional dose comparison parameters, normalized agreement test (NAT) values and the NAT index, are introduced and compared with an ideal dose comparison parameter. In this article, we analyze a clinically based two-dimensional (2D) quantitative dose comparison case using a wide range of new and old comparison tools. In doing so, we address the benefits and limitations of man...
background: for an effective treatment planning in brachytherapy, it is necessary to know the accurate source dosimetric information such as air kerma strength, exposure rate constant, dose rate constant and redial dose distribution. the usual method to determine these factors is thermo luminescent dosimeter (tld) dosimetry. nowadays, another more accurate method is known to be the monte carlo ...
Background: Palladium-103 (103Pd) is a brachytherapy source for cancer treatment. The Monte Carlo codes are usually applied for dose distribution and effect of shieldings. Monte Carlo calculation of dose distribution in water phantom due to a MED3633 103Pd source is presented in this work. Materials and Methods: The dose distribution around the 103Pd Model MED3633 located in the center of 30×...
This study investigates the temperature and thermal dose of a tumor in hyperthermia therapy with non-local equilibrium. The thermal model assumes the tissue with blood vessel distribution as a porous media and uses the convection terms instead of perfusion terms in energy conservation equations for both tissue and blood. By using numerical method, this study calculates the temperature and therm...
Total body irradiation (TBI) is a kind of external beam radiotherapy which is used in conjunction with chemotherapy with the purpose of immunosuppression before bone marrow transplantation. As recommended by AAPM dose distribution uniformity in TBI is very important and dose variation must be within ±10% of prescription dose. Patients treatment geometry for TBI techniques fall into two co...
A Fast Fourier Transform method for calculating the three-dimensional dose rate distribution for murine, human-tumor xenografts is outlined. The required input includes evenly-spaced activity slices which span the tumor. Numerical values in these slices are determined by quantitative 125I autoradiography. For the absorbed dose-rate calculation, we assume the activity from both 131I- and 90Y-lab...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید