نتایج جستجو برای: selective membrane electrode

تعداد نتایج: 631334  

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه شیراز - دانشکده علوم پایه 1392

a novel and ultra low cost isfet electrode and measurement system was designed for isfet application and detection of hydronium, hydrazinium and potassium ions. also, a measuring setup containing appropriate circuits, suitable analyzer (advantech board), de noise reduction elements, cooling system and pc was used for controlling the isfet electrode and various characteristic measurements. the t...

Journal: :Electrochimica Acta 2022

Voltammetric ion-selective electrodes (ISEs) based on poly(3-octylthiophene) (POT) in connection with ultra-thin membranes formulated different selective receptors (i.e., ionophores) are proposed for detection of lead, copper and silver ions (Pb2+, Cu2+ Ag+). The working mechanism the POT-membrane electrode is interconnected charge transfer processes both sides membrane, overall process dependi...

Journal: :Boletín de la Sociedad Chilena de Química 2002

Journal: :Chemistry Journal of Moldova 2010

A PVC ion-selective membrane electrode based on Cd-tetraphenyl porphyrine as a carrier was prepared fordetermination of MnO4- ion. This electrode revealed good selectivity toward permanganate ion over a widevariety of anions. Effects of some experimental parameters such as nature of the plasticizer, the amounts ofcarrier and additive, and concentration of the internal solution on the potential ...

Journal: :iranian journal of pharmaceutical research 0
farhad ahmadi 1- drug delivery research center, faculty of pharmacy, kermanshah university of medical sciences, kermanshah, islamic republic of iran. 2-department of medicinal chemistry, faculty of pharmacy, kermanshah university of medical sciences, kermanshah, islamic republic of iran. nasim assadi department of medicinal chemistry, faculty of pharmacy, kermanshah university of medical sciences, kermanshah, islamic republic of iran.

a novel potentiometric ion-selective pvc membrane sensor for analysis of atorvastatin (at) in pharmaceutical preparations based on atorvastatin-(tetraphenyl borate), (at-(tpb)2) as sensing element, tetraphenyl borate as additive and tris-2-ethyl-hexyl phosphate (top) as plasticizer solvent was prepared. the electrode shows a good nernestian response over the concentration range of 0.09–5586 µg ...

Journal: :journal of physical & theoretical chemistry 2011
m. kia a. islamnezhad sh. shariati

in order to preparing strontium ion selective electrode 6-(4- nitropheny1)-2-pheny14, 4- dipropy1-3, 5-diaza-bicyclo [3, 1, 0] hex-2-ene (npdbh) was used as an ionophore. this electrode responds to sr (ii)ion with a sensitivity of 28.2 ± 0.5 mv/decade over the range 1.0 x 10-6 to 1.0 mat ph 3.0-10.0. thelimit of detection was 2.4 x 10-7 m. the influences of membrane composition, the ph of the t...

Ali Benvidi, Hamid Reza Zare, Mehdi Elahizadeh Rasoul Vafazadeh

An iodide ion-selective PVC membrane sensor based on copper (Π)-bis-Nphenilsalicyldenaminatocomplex as a novel sensing material is successfully developed. Theelectrode showed a good selectivity for iodide ion with respect to common inorganic anions. Thesensor exhibited a good linear response with slope of _58.6 ± 0.4 mV per decade over theconcentration range of 5.0 × 10-6 to 1.0 × 10-1 mol L-1,...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه گیلان - دانشکده علوم پایه 1385

الکترود یون گزین حساس به داروی آتنول بر پایه کمپلکس تجمع یونی آتنولول فسفوتنگستات در یک غشای pvc و نرم کننده غشاء استوفنون طراحی و ساخته شد. اثر ترکیب غشا دما زمان آماده سازی الکترود ph محلول آزمایشی و یون های مزاحم برعملکرد الکترود مورد بررسی قرار گرفت. برگشت پذیری گزینش پذیری و زمان پاسخ الکترود نیز مطالعه شد. الکترود یون گزین مربوطه پاسخ نرنستی در گستره غلظتی وسیع 10*1 به توان 2- و 10*1 به ت...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید